2

15. 03. 21. Document Number  671846

Nuaire | 

Western Industrial Estate 

Caerphilly 

CF83 1NA 

|

 

nuaire.co.uk

DRI-ECO-HEAT-HCS

Installation Manual

• 

If the unit is required to switch off in the event of smoke/CO detection, alarms are available with 
separate relay bases from 3rd party companies. This is a mandatory requirement for all units 
installed in a 3 Storey property. 

• 

To ensure efficient filtration of particulate matter the air filters should be replaced every 5 years 
as per our recommended maintenance.

1.1 Hazard Symbols

 

GENERAL WARNING 

 

 

Signifies a general warning regarding hazard specified by supplementary information.

 

ELECTRIC SHOCK

 

 

 

This unit must be completely electrically isolated before any panels are removed. Check  

 

 

mains supply and control connections. 

 

ROTATING PARTS 

 

 

 

This unit contains fast moving rotational parts which may start automatically. It is the  

 

 

sole responsibility of the installer to adequately guard these components.

  

REFER TO INSTRUCTION MANUAL

 

 

Read and understand the installation and maintenance manual before installing,    

 

 

operating or maintaining this product.

1.2 Important Information

This manual contains important information on the safe and 
appropriate assembly, transport, commissioning, operation, 
maintenance, disassembly and simple troubleshooting of the product.

While the product has been manufactured according to the accepted 
rules of current technology, there is still a danger of personal injury or 
damage to equipment if the following general safety instructions and 
the warnings contained in these instructions are not complied with.

Read these instructions completely and thoroughly before 
working with the product.

Keep these instructions in a location where they are accessible 
to all users at all times.

Always include the operating instructions when you pass the 
product on to third parties.

1.3 Personal Protective Equipment

The following minimum Personal Protective Equipment (PPE) is 
recommended when interacting with Nuaire product:

Protective Steel Toed Shoes - 

when handling heavy objects.

 

Full Finger Gloves (Marigold PU800 or equivalent) - 

when 

handling sheet metal components. 

Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent) 

- when conducting light work on the unit requiring tactile 
dexterity. 

Safety Glasses

 - when conducting any cleaning/cutting operation 

or exchanging filters. 

Reusable Half Mask Respirators 

- when replacing filters which 

have been in contact with normal room or environmental air.

Nuaire would always recommend a site specific risk assessment by a 
competent person to determine if any additional PPE is required. 

2.0 INTRODUCTION

The DRI-ECO-HEAT-HCS provides whole home ventilation using 
the Positive Input Ventilation principle. The concept is to introduce 
fresh, filtered air into the dwelling at a continuous rate, encouraging 
movement of air from inside to outside. To achieve this the unit is 
mounted in the loft space, drawing air through the filters and inputting 
it, at ceiling level, into the property.

The DRI-ECO-HEAT-HCS fan unit includes an internal sensor to 
regulate the fan speed according to the temperature of the loft. The 
internal sensor is to increase airflow to the dwelling when the loft is 
warmer than the house. The units ‘Fixed Temperature Heat Recovery’ 
strategy shall be achieved via a sensor located in the unit and shall 
improve energy performance accordingly. This unit has all the controls 
for the fan in the ceiling vent allowing the user to control, programme 
and monitor the unit from inside the property. A heater section 
incorporating a 400W heating element shall be fitted to the fan unit. 
It shall be electronically controlled so as to minimise energy use. A 
temperature sensor shall be fitted to the outlet of the heater and will 
control the output of the heater in an attempt to maintain the set 
point. The set point will be adjustable between 5˚C and 15˚C.

Once installed, the airflow can be set to suit the house size and, if 
required, the way it responds to the temperature changes within.

3.0 GENERAL INSTALLATION

Successful operation of the fan depends entirely upon the unit being 
installed strictly in accordance with these instructions.

Please read through this guide in its entirety before commencing 
installation and follow step by step to ensure a satisfactory completion.

Whilst the installation of the unit may be achieved by suitable persons, 
the provision of the electrical supply and the connection of the unit to 
the mains must be carried out by a qualified electrician.

Warning: Isolate from power supply before removing any covers. 
During installation/maintenance ensure all covers are fitted before 
switching on the mains supply.

Содержание DRI-ECO-HEAT-HCS

Страница 1: ...ack of experience and knowledge unless they have been given supervision or instruction concerning the safe use of the appliance by a person responsible for their safety Children shall not play with th...

Страница 2: ...ing tactile dexterity Safety Glasses when conducting any cleaning cutting operation or exchanging filters Reusable Half Mask Respirators when replacing filters which have been in contact with normal r...

Страница 3: ...ience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Clea...

Страница 4: ...xible duct maximum length 2m is connected to the fan unit by inserting the duct over the fan outlet and held in place using the supplied cable tie This method is repeated when connecting the duct to t...

Страница 5: ...www kiddesafetyeurope co uk Aico Ltd www aico co uk This is a mandatory requirement for all units installed in a 3 Storey property POWER SUPPLY FAN UNIT Mains power Smoke CO detector with NO NC contac...

Страница 6: ...rol are electrically isolated from the mains supply and switched live supply It is important that maintenance checks are recorded and that the schedule is always adhered to in all cases the previous r...

Страница 7: ...erature This is normal see temperature control options 15 0 AFTER SALES AND REPLACEMENT PARTS For technical assistance or further product information including spare parts and replacement components p...

Страница 8: ...8 15 03 21 Document Number 671846 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk DRI ECO HEAT HCS Installation Manual NOTES...

Отзывы: