15. 03. 21. Document Number 671846
Nuaire |
Western Industrial Estate
|
Caerphilly
|
CF83 1NA
|
nuaire.co.uk
DRI-ECO-HEAT-HCS
Installation Manual
•
If the unit is required to switch off in the event of smoke/CO detection, alarms are available with
separate relay bases from 3rd party companies. This is a mandatory requirement for all units
installed in a 3 Storey property.
•
To ensure efficient filtration of particulate matter the air filters should be replaced every 5 years
as per our recommended maintenance.
1.1 Hazard Symbols
GENERAL WARNING
Signifies a general warning regarding hazard specified by supplementary information.
ELECTRIC SHOCK
This unit must be completely electrically isolated before any panels are removed. Check
mains supply and control connections.
ROTATING PARTS
This unit contains fast moving rotational parts which may start automatically. It is the
sole responsibility of the installer to adequately guard these components.
REFER TO INSTRUCTION MANUAL
Read and understand the installation and maintenance manual before installing,
operating or maintaining this product.
1.2 Important Information
This manual contains important information on the safe and
appropriate assembly, transport, commissioning, operation,
maintenance, disassembly and simple troubleshooting of the product.
While the product has been manufactured according to the accepted
rules of current technology, there is still a danger of personal injury or
damage to equipment if the following general safety instructions and
the warnings contained in these instructions are not complied with.
•
Read these instructions completely and thoroughly before
working with the product.
•
Keep these instructions in a location where they are accessible
to all users at all times.
•
Always include the operating instructions when you pass the
product on to third parties.
1.3 Personal Protective Equipment
The following minimum Personal Protective Equipment (PPE) is
recommended when interacting with Nuaire product:
•
Protective Steel Toed Shoes -
when handling heavy objects.
•
Full Finger Gloves (Marigold PU800 or equivalent) -
when
handling sheet metal components.
•
Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent)
- when conducting light work on the unit requiring tactile
dexterity.
•
Safety Glasses
- when conducting any cleaning/cutting operation
or exchanging filters.
•
Reusable Half Mask Respirators
- when replacing filters which
have been in contact with normal room or environmental air.
Nuaire would always recommend a site specific risk assessment by a
competent person to determine if any additional PPE is required.
2.0 INTRODUCTION
The DRI-ECO-HEAT-HCS provides whole home ventilation using
the Positive Input Ventilation principle. The concept is to introduce
fresh, filtered air into the dwelling at a continuous rate, encouraging
movement of air from inside to outside. To achieve this the unit is
mounted in the loft space, drawing air through the filters and inputting
it, at ceiling level, into the property.
The DRI-ECO-HEAT-HCS fan unit includes an internal sensor to
regulate the fan speed according to the temperature of the loft. The
internal sensor is to increase airflow to the dwelling when the loft is
warmer than the house. The units ‘Fixed Temperature Heat Recovery’
strategy shall be achieved via a sensor located in the unit and shall
improve energy performance accordingly. This unit has all the controls
for the fan in the ceiling vent allowing the user to control, programme
and monitor the unit from inside the property. A heater section
incorporating a 400W heating element shall be fitted to the fan unit.
It shall be electronically controlled so as to minimise energy use. A
temperature sensor shall be fitted to the outlet of the heater and will
control the output of the heater in an attempt to maintain the set
point. The set point will be adjustable between 5˚C and 15˚C.
Once installed, the airflow can be set to suit the house size and, if
required, the way it responds to the temperature changes within.
3.0 GENERAL INSTALLATION
Successful operation of the fan depends entirely upon the unit being
installed strictly in accordance with these instructions.
Please read through this guide in its entirety before commencing
installation and follow step by step to ensure a satisfactory completion.
Whilst the installation of the unit may be achieved by suitable persons,
the provision of the electrical supply and the connection of the unit to
the mains must be carried out by a qualified electrician.
Warning: Isolate from power supply before removing any covers.
During installation/maintenance ensure all covers are fitted before
switching on the mains supply.