NuAire AIRMOVER DSA Series Скачать руководство пользователя страница 7

Flexible Connector 

(Double Flange)

Square with a pair of proprietary quickfit flanges. Flexible
duct material is flameproof. The open end is a light gauge
galvanised steel spigot.
Heat resistance is 132

o

C with excellent resistance to

chemicals, ozone, oil and grease. The connector is airtight,
waterproof and tested to BS476 Part 7.

Dimensions

(mm)

Unit

Code

DSA

A

B

DSDF4

500

650

171

DSDF5

560/630

812

171

Flexible Connector 

(Single Flange)

Square with a single proprietary quickfit flange. Flexible
duct material is flameproof. The open end is a light
gauge galvanised steel spigot.
Heat resistance is 132

o

C with excellent resistance to

chemicals, ozone, oil and grease. The connector is airtight,
waterproof and tested to BS476 Part 7.

Dimensions

(mm)

Unit

Code

DSA

A

B

C

DSFX4

500

650

50

168

DSFX5

560/630

812

50

168

Dimensions (continued)

Installation and Maintenance  

AIRMOVER DSA AXIAL UNITS

7

Wire Guard

Mild steel mesh guard. Polyethelene plastic coated
c/w 4 corner fixing holes matching fan unit.

Dimensions

(mm)

Unit

Code

DSA

A

B dia

DSGD4

500

682

11

DSGD5

560/630

844

11

4 holes 

B dia.

A sq

Dimensions

(mm)

Code

A

B

DAV 1

30

50

DAV 2

40

75

DAV 3

40

75

DAV 4

40

75

DAV 5

40

75

DAV 6

40

75

Note:

Mounting feet
supplied with
DSA units.

B

A

A sq

B

C

Double Flexible Connector

A sq

B

Resilient
Mountings 

(typical)  see page 5 for
further information

Содержание AIRMOVER DSA Series

Страница 1: ...arefully to avoid damage or distortion Units are provided with four lifting eyes If spreaders are used they should be positioned as near the end flanges as possible and in such a way that slings or we...

Страница 2: ...ttach silencers directly to the airmovers using bolts at the corners b For units being prepared for horizontal mounting attach the resilient mountings and mounting feet at the corner holes of the flan...

Страница 3: ...ff Testing Remove the access panel from the Airmover Switch on the local isolator by others Run the fan just sufficiently long to ensure that it rotates Switch off During run down by observation throu...

Страница 4: ...ance AIRMOVER DSA AXIAL UNITS Installation Vertical Mounting Fan unit Free air space Free air space Free air space Flow Flow Free air space Detail of resilient mounting onto steelwork Steelwork by oth...

Страница 5: ...er Square Axial Code M8 unit fixings supplied Mounting Foot details Note Four mounting feet are supplied with each unit or silencer see main dimension drawings M8 fixing screws are included 65 25 50 4...

Страница 6: ...11 11 21 32 Fan Size Dimensions mm A B C D E dia Weight kg Dimensions D ctrs Silencer A sq 4 Holes E dia B C overall DSA 500 DSA560 630 DSA Code Dimensions mm Weight kg A B C C D E Short Long Short L...

Страница 7: ...l spigot Heat resistance is 132o C with excellent resistance to chemicals ozone oil and grease The connector is airtight waterproof and tested to BS476 Part 7 Dimensions mm Unit Code DSA A B C DSFX4 5...

Страница 8: ...speed as required Replacement of Parts Isolation BEFORE COMMENCING MAKE SURE THAT THE AIRMOVER IS EXTERNALLY ISOLATED FROM THE ELECTRICAL SUPPLY Parts For the ordering of spare and replacement parts s...

Страница 9: ...loosened in the hub and the assembly of impeller and bush can be drawn from the shaft Remove the screw and separate the impeller and bush Fitting a taperlock impeller to a motor Making sure that tape...

Страница 10: ...cable entry When delivered fan units fitted with a permanent capacitor motor will have links fitted When used with a speed control one link must be removed and the motor wired as shown in the appropr...

Страница 11: ...1 phase 50Hz supply T1 T2 X L N L N L2 N N L1 Speed Control TRANSFORMER 1 phase L N Fan unit Control To Starter Control Circuit where fitted NOTE Remove link between X L when using a speed control ST...

Страница 12: ...8 37 EC Machinery Directive 93 44 EEC Amendment to the Machinery Directive Applied Harmonised Standards EN292 1 EN292 2 EN294 EN29001 Applied National Standards BS848 Parts One Two and Five Signature...

Страница 13: ...ge Directive Applied Harmonised Standards E50081 1 EN50082 1 EN60204 1 EN60335 2 80 Basis of Self Attestation Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No FM 149 Signature of...

Страница 14: ...orientation 4 2 Where installation accessories are supplied with the specified equipment eg wall mounting brackets They are to be used to support the equipment only Other system components must have s...

Страница 15: ...15...

Страница 16: ...y from time to time make it necessary to alter the design performance and dimensions of equipment and the right is reserved to make such changes without prior notice 16 Service As a manufacturer NuAir...

Отзывы: