STORING OF THE PORTABLE HVAC SPRAYER
Your Turbo Tank HVACR Rinsing Sprayer should be stored in such a way to protect it from freezing.
Do not store this unit outdoors or in areas where temperatures will fall below 0°C (32°F). This can
cause extensive damage to this unit and void the warranty. Before storing, follow these shut down
instructions:
DRAIN WATER FROM MACHINE:
1. Turn off the switch, squeeze the lever to release pressure. Remove the nozzle and squeeze
handle lever to drain the water. Empty the water from the tank. Turn the unit on and run it for
approximately 30 seconds without the nozzle while engaging the handle lever.
2. Lower one end of the hose, engage the lever on the handle and allow the water to drain from
the hose.
3. Remove and place the spray gun and power cord in the mesh storage compartments.
4. If the unit must be stored under freezing condition, or will be stored for more the 30 days, a
pump winterizer/protector or a non-toxic RV anti-freeze can be used to prevent freezing and
reduce mineral deposits.
ADD ANTI-FREEZE AS FOLLOWS:
1. Pour approximately 3/4 gallon (3 liters) of RV anti-freeze into tank.
2. Connect high pressure hose, nozzle, and power cord.
3. Turn unit on, squeeze lever until a steady stream of RV anti-freeze in present.
4. Turn unit off. Squeeze handle lever to release pressure.
5. Remove and place the spray gun and power cord in the mesh storage compartment.
USING PRESSURE SPRAYER AFTER STORING WITH ANTI-FREEZE:
1. Drain RV anti-freeze. (follow steps 1 and 2 from Drain Water from Machine)
2. Run 1 tank of fresh water through system before using and ensure that all anti-freeze is purged
from the system.
WARNING:
USE ONLY RV ANTIFREEZE. OTHER FORMULATED ANTI-FREEZE PRODUCTS FOR
HVAC APPLICATIONS CAN DAMAGE PUMP AND VOID WARRANTY.