background image

NTI XTENDEX 300 Foot DVI Video and IR Extender 

 

3

 
 
 

LIMITATIONS 

 

 

The use of CAT5e unshielded or all shielded CATx cabling will reduce the maximum distance and resolution.  

 
 
 
 

PREPARATION FOR INSTALLATION

 

 

 

Locations should be chosen for the monitor that also has space to connect the Remote unit within the distance provided by 
the cables.    If extension cables are needed, contact NTI for the cables required.  

 

 

The CATx cables must be run to the locations where the Remote and Local units will be connected.   Be careful to route the 
cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the video signal  
(i.e. AC motors, welding equipment, fluorescent lighting, etc.).  

 

 

All cables should be installed in such a way that they do not cause stress on their connections to the equipment.   Extended 
lengths of cable hanging from a connection may interfere with the quality of that connection.    Secure cables as needed to 
minimize this. 

 

 

Properly shut down and disconnect the power from the video source and monitor to be separated.    If other equipment is 
involved whose connections are being interrupted, be sure to refer to the instruction manuals for that equipment for proper 
disconnection and reconnection procedures before proceeding.   

 
 

WARNING: The CATx connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series 
products must be wired straight through (pin 1 to pin 1, pin 2 to pin 2, etc.)  The use of a CROSSOVER CABLE will 
damage the extender and void your warranty. 

 
 
 
 
 

Содержание XTENDEX ST-C6DVIA-IR-R-300

Страница 1: ...MAN135 Rev Date 9 25 2018 ST C6DVI IR 300 300 FOOT DVI VIDEO AND IR EXTENDER Installation and Operation Manual XTENDEX Series ...

Страница 2: ...tion only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the product design without reservation and without notification to its users Note CATx connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground outdoors or between buildings WARNING Outdoor or underground runs of CATx...

Страница 3: ...p 5 Infrared Control 6 Technical Specifications 7 Interconnection Cable Wiring Method 8 Troubleshooting 8 Warranty Information 9 TABLE OF FIGURES Figure 1 Connect the extended video display to the Remote Unit 4 Figure 2 Connect the XTENDEX Local Unit to the source 4 Figure 3 Connect CATx cable 5 Figure 4 Connect the AC adapter to the Remote Unit 5 Figure 5 Connect IR Emitter and Receiver 6 Figure ...

Страница 4: ...lution to 1920 x 1200 and HDTV resolutions to 1080p see page 8 for more details Transmits DVI signal over one CATx cable Only one power supply is necessary Power supply can be connected to either the local or remote unit Supports a DVI monitor HDCP 1 2 compliant Supports the DDC2B protocol Supports 480p 720i p and 1080i p video formats MATERIALS Materials Included with ST C6DVI 300 kit NTI ST C6DV...

Страница 5: ... for connecting the CAT5e 6 6a 7 cable between the Local and Remote units 3a Yellow LED traffic indicator illuminates when there is communication between the local and remote units 3b Green LED power indicator illuminates when power has been supplied to the unit 4 DVI In DVI female video connector for connecting an DVI cable between the Local Unit and the video source 5 IR In 3 5mm Stereo Jack for...

Страница 6: ... welding equipment fluorescent lighting etc All cables should be installed in such a way that they do not cause stress on their connections to the equipment Extended lengths of cable hanging from a connection may interfere with the quality of that connection Secure cables as needed to minimize this Properly shut down and disconnect the power from the video source and monitor to be separated If oth...

Страница 7: ... Remote Unit without putting strain on the cables 2 Connect a DVI IS xx MM to the female DVI video connector labeled DVI Out on the Remote Unit Figure 1 Connect the extended video display to the Remote Unit Installing The Local Unit Connect a DVI IS xx MM between the video source and the DVI Video In connector on the Local Unit Figure 2 Connect the XTENDEX Local Unit to the source ...

Страница 8: ...age to devices connected to the Ethernet may result Plug in and Boot Up 1 Plug the power cord from the monitor into the power outlet 2 Connect an AC adapter power connector to the 24VDC port on the Remote Unit or the Local Unit Plug the AC adapter into a power outlet The green LED on the RJ45 connector of both the Remote and Local Units should illuminate indicating that a proper power connection h...

Страница 9: ...R OUT port on the Local unit Position the end of the receiver such that the signal from the remote control can easily reach the IR sensor Position the end of the emitter such that the extended signal can be sent to the video source Figure 5 Connect IR Emitter and Receiver 3 5MM Mono Plug IR Emitter 3 5MM Stereo Plug IR Receiver IR RCVR 3 IR EMTR 3 Note The IR Emitter and Receiver work within a fre...

Страница 10: ... 100V to 240VAC at 50 or 60Hz 24VDC 1 0A via AC Adapter Enclosure type Electro galvanized steel black powder coated Size In WxDxH Local and Remote 3 09 x 3 49 x 1 08 Compliance Certifications CE RoHS Distances and Resolutions for CAT5e CAT6 CAT6a and CAT7 Cables Solid and Stranded Unshielded UTP and Shielded STP Twisted Pair Resolutions Cable Length ft Max Resolution Cable Length ft Max Resolution...

Страница 11: ...et is live and AC adapter is plugged in Make sure 24VDC jack is fully connected No Video on monitor One or more video cables is loose or disconnected No power to Remote Unit CATx cable is not connected CATx cable is too long DVI cable is too long Check all video cable connections Make sure Power LED is illuminated on local and remote If not see solutions for first problem above With all the cables...

Страница 12: ...o 2 years from the date of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com return policy html for information regarding repairs and or returns A return authorization number is required for all repairs returns Manual 135 Rev 9 25 18 ...