background image

Rally 1200 

5

 

 

 

WARNING: Failure to observe these 

instructions  can  cause personal injury to the machine 
operator, and/or bystanders.
 

 

Caution warnings are used to warn of immediate hazards 

that  cause severe personal injury or death. 

 

Always wear eye protection, gloves, long sleeve shirt and pants. 

  

To reduce the risk of fire, electrical shock, or injury: 

1.

 

Read quick start guide and manual prior to use. 

2.

 

Unplug machine before service. 

3.

 

Use only manufacturer recommended attachments 
and replacement parts. 

4.

 

Never upgrade or repair this equipment without 
authorization from the manufacturer. 

5.

 

Do not unplug the unit by pulling on the cord. 

6.

 

Do not run over the cord with any wheeled product. 

7.

 

Do not pull or carry by the cord. 

8.

 

Do not use if the cord is damaged. 

9.   Do not use in areas with flammable or combustible 

material are present. 

10.

 

Do not allow to freeze. 

11.

 

Do not store on its side with liquids in the recovery or solution tanks. 

12.

 

Use only the appropriate handles to move and lift unit. Do not use 
any  other parts of this machine for this purpose. 

13. Keep hair, loose clothing, fingers, and all parts of the body away from 

all openings and moving parts. 

14. Use extra care when using on stairs. 
15. To reduce the risk of fire or electric shock, do not use this machine with 

a solid-state speed control device. 

16. The voltage and frequency indicated on the name plate must 

correspond to the wall receptacle supply voltage. 

17. When cleaning and servicing the machine, local or national regulations 

may apply to the safe disposal of liquids which may contain: chemicals, 
grease, oil, acid, alkaline, or other dangerous liquids. 

 

Preparation 

1.

 

Remove furniture and other items from the area you are going to clean. 

2.

 

Vacuum carpet and upholstery, and remove debris. 

3.

 

Protect cabinets, walls and painted surfaces with drop cloths or plastic. 

4.

 

Inspect power cords for damage. 

 
 
 
 
 
 
 
 

Operating Instructions 
1.

 

Fill Solution Tank. To use the Auto-Fill feature, hook up the male end 
of a garden hose to the female adapter on the outside of the 
solution  tank and turn on the water supply. The float valve in the 
tank will  automatically turn off when the tank is full. 

2.

 

Plug in power cords: Extractor Model: Using two separate circuits/ 
breakers, plug in the grounded power cables as previously instructed 
using the proper grounding techniques. The green indicator to the 
right  of the PSI gauge will illuminate and sound a tone when plugged 
into separate circuits/breakers. 

i.

 

Activate the switched using the following steps: 

ii.   When the hoses and tool are attached, turn pump switch on. 
iii.  Pull the trigger on the wand until water runs through the lines. 

If the pump does not prime, turn the pump switch off and 
disconnect the hoses. Connect the supplied priming hose 
and  put the open end into the vacuum barb and turn on the 
vacuum motor and solution pump. Seal the hose to the barb 
with your hand until water is visible running through the hose. 
Turn both switches on and repeat from step i. 

3.

 

If using the Pump-Out feature hook up the female end of a garden 
hose  to the male adapter on the motor base and run it to a sewer drain 
(ex.  Toilet, janitors sink). Turn on the Waste Pump switch. 

4.

 

Pressure Adjustment: Pressure will only show on the gauge while the 
tool is being sprayed. When the tool is not being sprayed the 
pressure will read 0 psi. 

i.

 

To decrease pressure, turn the black knob on the motor 

base counter-clockwise. 

ii.

 

To increase pressure, turn the black knob on 

the motor base clockwise. 

iii.

 

Make your adjustment and spray the tool to check the 

pressure. Re-adjust as needed to set the desired 
pressure. 

5.

 

To prevent motor or internal damage, use a foam control solution in the 

recovery tank. Remember to check for buildup in both the recovery 
and solution tanks! 

6.

 

Empty the recovery tank when the internal shut off switch disengages 
the vacuum. Attach the 45° drain elbow to the drain spout located in 
the  back and lift the dump valve to empty the tank. 

7.

 

Squeeze the wand or tool’s trigger for 5 seconds after turning the 
power  switches off to relive and existing line pressure. 

8.

 

When the machine is off: unplug the power cables, remove solution, 
vacuum, auto-fill and auto-dump hoses, and empty the recovery tank 
by attaching the 45° drain elbow. 

 
Machine Storage 

1.

 

Before storing the machine, drain, rinse and dry both the tanks  and 
vacuum hoses of any residual water. 

2.

 

Store standing upright in a dry enclosed area. 

3.

 

Leave the recovery tank lid open for better air circulation. 

4.

 

If storing in freezing temperatures, take extra precautions to  make 
sure the machine and solution systems are completely  drained and 
dry. 

 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание RALLY 1200

Страница 1: ...S A 3115 Frenchmens Road I Toledo OH 43607 I Ph 419 531 2121 I Fax 419 531 3761 I www nss com OWNER SMANUAL RALLY 1200 Specifications RALLY 1200 h t t p s h a r r i s s u p p l y i n d c o m T o O r...

Страница 2: ...njury 4 Preparation 5 Operating Instructions 5 Maintenance Schedule 6 Filter Maintenance 6 Vacuum Stack filters 6 Pump filters In line Filter 6 Trouble shooting 6 Pump does not work properly 6 Vacuum...

Страница 3: ...re finished 1 Take the vacuum hose off the wand and put it into the front tank and vacuum out the remaining cleaning chemicals to the recovery tank dump the water into a bucket or toilet 2 Run clean w...

Страница 4: ...s extended tab into place with a metal screw However grounding adapters are not approved for use in Canada Again be sure to check the grounding pin for damages and replace if necessary The Green or G...

Страница 5: ...bles as previously instructed using the proper grounding techniques The green indicator to the right of the PSI gauge will illuminate and sound a tone when plugged into separate circuits breakers i Ac...

Страница 6: ...ery tank lid 2 Remove pump out filter by turning counter clockwise 3 Rinse the filter with water from the inside out 4 Replace filter by turning clockwise 5 Replace recovery tank lid TroubleShooting T...

Страница 7: ...use the machine The buyer agrees and understands that the remedies provided under this limited warranty are the sole and exclusive remedies available to the buyer NSS reserves the right to change its...

Страница 8: ...ON PUMP ADJUSTABLE 400 TO 1200 PSI VACUUM MOTORS One 2 STAGE TAPERED FAN 2 1 HP SOUND LEVEL 75 Dba ISO 11201 DIMENSIONS HEIGHT 39 in 99 cm LENGTH 26 in 66 cm WIDTH 17 in 43 cm WEIGHT 150 lbs 68 kg RAL...

Отзывы: