background image

Brush Switch 

x

  The brush switch is located on the left side of the 

control column and it turns the brush on and off. 

x

  There is also a tilt switch in this circuit located 

under the brush head that only allows the brush to 
be turned on when the brush head is in the 
operating position.  

Circuit Breaker 

x

  There is one master circuit breaker located below 

the brush switch on the control column. 

Brush Head 

x

  The brush motor, Filter Bag and Flexiwall shield 

are located at the front of the machine. 

x

  The bag connects directly to the Flexiwall shield 

and has a snap that retains the rear of the bag. 

MAINTENANCE

ALWAYS turn OFF all machine switches 
before performing any maintenance or 
repairs to any equipment. 

Check the tension of the Drive Chain after the 
first 100 hrs of use and then every 90 days or 300 
hours as needed. For the chain tightening 
instructions see the maintenance section called 
90 Day Maintenance (300 Hours). 

Daily Maintenance 

Pad Installation / Changing

There is a wide range of pads available for many 
different burnishing applications. Consult your local 
NSS authorized distributor for application 
recommendations. 

x

  Lift the front of the machine up to the 90 degree 

position to view the pad driver and pad. 

x

  Make sure that the correct pad (7/8" to 1") X 27" is 

being installed.  

x

  Place the pad flat on the floor, and remove the 

center hole of the pad, step on the center of the 
pad to compress the edges around the center hole. 
This allows for easier installation of the pad 
centering cup. 

x

  With the machine in the pad changing position, 

carefully center the pad on the driver. 

Caution

:  Pads must be installed concentric (evenly 

aligned) with the outside edge of the pad driver. 
Failure to follow these precautions will cause 
excessive machine vibration, a reduction in pad life 
and produce unsatisfactory burnishing results. 

x

  Place the pad grabber in the center hole of the 

pad.

x

  Holding the pad driver and pad, push on the pad 

grabber until the spring clip has clicked twice. 

Caution:  

Failure to install the pad grabber tightly 

may allow the pad to be thrown from the driver. 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание CHARGER 2717 DB

Страница 1: ...l air openings free of dust lint hair etc x NEVER pick up anything that is burning or smoking such as cigarettes matches or hot ashes x NEVER allow this machine to be used as a toy Close attention is...

Страница 2: ...batteries only does not apply to gel cell or maintenance free batteries x ALWAYS check to ensure the battery water level covers the battery plates before charging x ALWAYS check water level after cha...

Страница 3: ...position by grasping the handle and moving it to the desired position x Turn on master switch and key switch if so equipped Wait until you hear a click the machine is now on See Machine Components fo...

Страница 4: ...r The battery charger is located on top of the battery box cover x This high efficiency battery charger is designed for onboard operation Master Switch x The master switch is located on the top right...

Страница 5: ...e of pads available for many different burnishing applications Consult your local NSS authorized distributor for application recommendations x Lift the front of the machine up to the 90 degree positio...

Страница 6: ...on With the master switch turned off put the brush head into the pad change position Turn the brush switch on then the master switch on the machine should turn on x If the machine does not turn on and...

Страница 7: ...grade bearing grease Failure to lubricate casters will cause the machine to maneuver with difficulty and premature failure of the caster will result x Lubricate the drive wheel bearings with an indust...

Страница 8: ...acid when installing batteries See Battery Warnings on page 2 x Remove the side panel and top cover There are two bolts one in each corner on top of the side panel and two nuts one in each corner at...

Страница 9: ...d of the gas spring against a hard surface and push on it If you can compress it it must be replaced If you can not compress it it is most likely OK Pad Pressure Adjustment The NSS Charger 2717 DB is...

Страница 10: ...6 is again displayed after interrupting AC power for at least 10 seconds the charger must be brought to a qualified service depot Battery Maintenance Instructions 1 For flooded lead acid batteries reg...

Страница 11: ...y Short run time on battery charge Incorrect Algorithm setting in battery charger for battery pack installed in machine Check Algorithm setting in battery charger and change if necessary Battery charg...

Страница 12: ...ter The brush motor is exceeding the current limit set in the controller Check the gas springs for wear Check the brush pressure set collars for proper adjustment Check pad driver and Flexiwall shield...