Every 6 Months                         
(Every 600 Hours) 

 

Call your Authorized NSS Distributor / Service 
Station to have the following services performed. 

 

Verify that all daily, weekly, monthly and quarterly 
maintenance has been performed. 

 

Inspect Brush Motor carbon brushes for wear.  

 

  Using compressed air, blow the accumulated carbon 

brush dust out of the motor. 

  Replace carbon brush when they measure ½” or less 

in length. 

  Failure to replace carbon brushes will cause poor 

machine performance and possible motor damage. 

Check the condition of the batteries.  

 

  A battery may be checked using a Hydrometer to 

check the specific gravity (strength) of the acid in 
each cell. Variations in readings occur due to the 
chemical reaction taking place during use.  

  Always check the specific gravity when the battery is 

fully charged.  

  Replace batteries as needed.  

Battery Installation: 

  Turn off all switches. Disconnect battery pack from 

the machine. 

 

ALWAYS

 wear eye protection, rubber gloves and 

protective clothing to avoid contact with battery acid 
when installing batteries. See Battery Warnings on 
page 2. 

 

 

 

  Remove the side panel and top cover. There are two 

nuts located in each corner inside the battery 
compartment and two nuts in each corner at the 
bottom of the cover. See above pictures. 

Note:

 The 

nuts are not visible from the outside of the machine. 

 

  The cover will still be attached to the side panel. 

Move them out of the way to install the Batteries. 

  Batteries are heavy – 

ALWAYS

 use two people to 

install batteries into machine. 

  Refer to wiring diagram located on the underside of 

the cover.  Align batteries in compartment the same 
as the old batteries or as shown on diagram. 

  Install battery cables the same as they were on the 

old batteries or as shown on wiring diagram located 
on the underside of the cover.  

 

NSS

 recommends replacing the battery cables when 

replacing batteries. 

  Tighten bolts and hex nuts with a wrench. 

  Install terminal boots over terminals to complete 

installation. 

CAUTION

: Do not short across two terminals with a wrench. 

CAUTION:  

Loose or improper battery connections will 

cause battery or machine damage and possible 
personal injury. 

 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание CHARGER 2022 AB

Страница 1: ...th any air opening blocked Keep all air openings free of dust lint hair etc NEVER pick up anything that is burning or smoking such as cigarettes matches or hot ashes NEVER allow this machine to be use...

Страница 2: ...es only does not apply to gel cell or maintenance free batteries ALWAYS check to ensure the battery water level covers the battery plates before charging ALWAYS check water level after charging and ad...

Страница 3: ...rom to pad changing position or operating position by grasping the handle and moving it to the desired position Turn on master switch and key switch if so equipped Wait until you hear a click the mach...

Страница 4: ...the battery box cover This high efficiency battery charger is designed for onboard operation Master Switch The master switch is located on the top right side of the control column and it turns the mac...

Страница 5: ...e front of the machine up to the 90 degree position to view the pad driver and pad Make sure that the correct pad size is installed Charger 2717 AB requires a 7 8 to 1 X 27 pad and a Charger 2022 AB r...

Страница 6: ...spray this machine with water or any liquids ALWAYS Check the tilt switch for proper operation With the master switch turned off put the brush head into the pad change position Turn the brush switch o...

Страница 7: ...tray can be drained using the hose at the right rear of the machine as shown above IMPORTANT Drain all liquids into an approved container and dispose of according to your local and federal regulations...

Страница 8: ...installing batteries See Battery Warnings on page 2 Remove the side panel and top cover There are two nuts located in each corner inside the battery compartment and two nuts in each corner at the bott...

Страница 9: ...duty applications It can be tuned to your specific application for optimum performance ONLY an authorized NSS Service Station should perform this adjustment The pad pressure can be adjusted by moving...

Страница 10: ...cell caps Removing the caps allows inspection of the liquid electrolyte sulfuric acid level in each cell AGM Absorbed Glass Mat batteries are sealed maintenance free batteries They do not have cell c...

Страница 11: ...tputs a battery voltage when the charger is not plugged in to AC to provide an Interlock function 2 Securely fasten the black ring terminal from the charger to the negative terminal NEG NEGATIVE of th...

Страница 12: ...iately and void the battery warrantee They can tell if this happened NEVER refill the batteries with well or tap water flooded cell batteries NEVER overfill the batteries flooded cell batteries NEVER...

Страница 13: ...nd replace if necessary Run time is less than when new Damaged defective battery s Check for fault codes on the battery charger during battery charging Have an authorized NSS Service Station check the...

Страница 14: ...lem continues call for service Fault code F37 appears in battery meter Potentiometer wired incorrectly Internal control system failure Check wiring Turn machine off and then on If problem continues ca...