NSS CHARGER 2022 AB Скачать руководство пользователя страница 5

 

 

 

 

Brush Switch 

  The brush switch is located on the left side of the 

control column and it turns the brush on and off. 

  There is also a tilt switch in this circuit located under 

the brush head that only allows the brush to be turned 
on when the brush head is in the operating position.  

Circuit Breaker 

  There is one master circuit breaker located below the 

brush switch on the control column. 

 

Brush Head 

 

 

 

  The brush motor, Filter Bag and Flexiwall shield are 

located at the front of the machine. 

  The bag connects directly to the Flexiwall shield and 

has a snap that retains the rear of the bag. 

 
 
 
 

MAINTENANCE 

 

ALWAYS turn OFF all machine switches 
before performing any maintenance or 
repairs to any equipment. 

 

Daily Maintenance 

 

Pad Installation / Changing  

  

 

There is a wide range of pads available for many 
different burnishing applications. Consult your local NSS 
authorized distributor for application recommendations. 

  Lift the front of the machine up to the 90 degree 

position to view the pad driver and pad. 

  Make sure that the correct pad size is installed. 

Charger 2717 AB requires a (7/8" to 1") X 27" pad 
and a Charger 2022 AB requires a (7/8" to 1") X 20" 
pad.  

  Place the pad flat on the floor, and remove the center 

hole of the pad, step on the center of the pad to 
compress the edges around the center hole. This 
allows for easier installation of the pad centering cup. 

  With the machine in the pad changing position, 

carefully center the pad on the driver. 

Caution

:  Pads must be installed concentric (evenly 

aligned) with the outside edge of the pad driver. Failure 
to follow these precautions will cause excessive 
machine vibration, a reduction in pad life and produce 
unsatisfactory burnishing results. 

  Place the pad grabber in the center hole of the pad. 

  Holding the pad driver and pad, push on the pad 

grabber until the spring clip has clicked twice. 

 

Caution:  

Failure to install the pad grabber tightly may 

allow the pad to be thrown from the driver. 

 

 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание CHARGER 2022 AB

Страница 1: ...th any air opening blocked Keep all air openings free of dust lint hair etc NEVER pick up anything that is burning or smoking such as cigarettes matches or hot ashes NEVER allow this machine to be use...

Страница 2: ...es only does not apply to gel cell or maintenance free batteries ALWAYS check to ensure the battery water level covers the battery plates before charging ALWAYS check water level after charging and ad...

Страница 3: ...rom to pad changing position or operating position by grasping the handle and moving it to the desired position Turn on master switch and key switch if so equipped Wait until you hear a click the mach...

Страница 4: ...the battery box cover This high efficiency battery charger is designed for onboard operation Master Switch The master switch is located on the top right side of the control column and it turns the mac...

Страница 5: ...e front of the machine up to the 90 degree position to view the pad driver and pad Make sure that the correct pad size is installed Charger 2717 AB requires a 7 8 to 1 X 27 pad and a Charger 2022 AB r...

Страница 6: ...spray this machine with water or any liquids ALWAYS Check the tilt switch for proper operation With the master switch turned off put the brush head into the pad change position Turn the brush switch o...

Страница 7: ...tray can be drained using the hose at the right rear of the machine as shown above IMPORTANT Drain all liquids into an approved container and dispose of according to your local and federal regulations...

Страница 8: ...installing batteries See Battery Warnings on page 2 Remove the side panel and top cover There are two nuts located in each corner inside the battery compartment and two nuts in each corner at the bott...

Страница 9: ...duty applications It can be tuned to your specific application for optimum performance ONLY an authorized NSS Service Station should perform this adjustment The pad pressure can be adjusted by moving...

Страница 10: ...cell caps Removing the caps allows inspection of the liquid electrolyte sulfuric acid level in each cell AGM Absorbed Glass Mat batteries are sealed maintenance free batteries They do not have cell c...

Страница 11: ...tputs a battery voltage when the charger is not plugged in to AC to provide an Interlock function 2 Securely fasten the black ring terminal from the charger to the negative terminal NEG NEGATIVE of th...

Страница 12: ...iately and void the battery warrantee They can tell if this happened NEVER refill the batteries with well or tap water flooded cell batteries NEVER overfill the batteries flooded cell batteries NEVER...

Страница 13: ...nd replace if necessary Run time is less than when new Damaged defective battery s Check for fault codes on the battery charger during battery charging Have an authorized NSS Service Station check the...

Страница 14: ...lem continues call for service Fault code F37 appears in battery meter Potentiometer wired incorrectly Internal control system failure Check wiring Turn machine off and then on If problem continues ca...

Страница 15: ...h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Страница 16: ...3761 NSS Enterprises Inc European Distribution Centre Unit II Pinfold Trading Estate 55 Nottingham Road STAPLEFORD NOTTINGHAM NG9 8AD ENGLAND U K PHONE 44 0115 939 1568 FAX 44 0115 949 0615 h t t p s...

Отзывы: