AGMs are to be charged with the Gel
setting.
State of Charge Indicators. Four additional
LEDs provide information about the charge level
of the batteries during charging.
o
30%, 60%, 90% and 100%.
Fault Indications. During charging, the charger
provides feedback about the charge process
and any problems detected. It will provide
feedback and signal the type of problem by
flashing LEDs as described below:
Changing the Battery Type Setting
The standard setting for the onboard battery charger
is Flooded/AGM. EXCEPTION: If your machine was
ordered from NSS equipped with Gel batteries, then
the charger was configured for Gel batteries at the
factory.
Configuring the Charger for Gel batteries.
1. Remove the top cover.
2. Pull the jumper off the board (position 1), and
then store the jumper for later use at position 2.
See photo below.
3. Reinstall the top cover.
Configure the Charger for Flooded/AGM batteries
Position 1
Remove
jumper for gel
Position 2
Storage Location
For jumper
Top cover
screws
https://harrissupplyind.com - To Order Parts Call 608-268-8080