![NSS CHAMP 3329 RB Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/nss/champ-3329-rb/champ-3329-rb_operation-manual_1714746011.webp)
2C02 Soft battery lockout occurred.
Battery Charge too low. Recharge battery.
2C03 Soft battery lockout 2 occurred.
Battery Charge too low. Recharge battery.
2F01 Tiller displaced error.
Throttle displaced on Power-up. Release throttle and then
re-engage throttle. Check Potentiometer settings (neutral).
3A00 Bad settings.
Illegal program parameter settings.
7000 Startup with push selected.
N/A
7001 Push activated in drive mode.
N/A
7500 Tiller comms timeout.
Problem with LCD Module or wiring. Check cable connection between controller
and LCD. Repair or replace as necessary.
7600 Soft brush motor disconnected error.
Check Brush Motor wiring and connections.
7601 Soft brush current fold back.
Check Brush Motor for excessive amp draw. Check for locked rotor conditions
(debris caught in brushes, gear box locked up, etc.). Repair or Replace as
necessary.
7602 Soft brush current fold back 2.
Check Brush Motor for excessive amp draw. Check for locked rotor conditions
(debris caught in brushes, gear box locked up, etc.). Repair or Replace as
necessary.
7603 Soft brush current fold back 3.
Check Brush Motor for excessive amp draw. Check for locked rotor conditions
(debris caught in brushes, gear box locked up, etc.). Repair or Replace as
necessary.
7604 Soft brush inhibit.
Check Brush Motor for excessive amp draw when starting.
Repair or Replace as necessary.
7605 Brush startup over current detection.
Check Brush Motor for excessive amp draw. Check for locked rotor conditions
(debris caught in brushes, gear box locked up, etc.). Repair or Replace as
necessary.
7700 Soft vacuum motor disconnected error Check Vac Motor wiring, connections and carbon brushes.
7701 Soft vacuum current fold back.
Check Vac Motor for excessive amp draw.
Repair or Replace as necessary.
7702 Soft vacuum current fold back 2.
Check Vac Motor for excessive amp draw.
Repair or Replace as necessary.
7703 Soft vacuum current fold back 3.
Check Vac Motor for excessive amp draw.
Repair or Replace as necessary.
7800 Traction motor fault -1.
Check Drive Motor wiring, connections.
7801 Traction motor over current error.
Check Drive Motor for excessive amp draw. Release Parking Break. Replace as
necessary.
7802 Soft traction motor in fold back state.
Traction Motor being overloaded or Fold back parameters set too low.
7803 Motor line voltages instability timeout.
Check Drive Motor wiring, Controller wiring, connections.
7880 Traction speed input out of range.
Check Drive Motor wiring, Controller wiring, connections.
7900 Emergency stop error.
N/A
7901 Soft belly button activated.
N/A
8000 Service mode.
N/A
9000 Brushes not fitted.
N/A
https://harrissupplyind.com - To Order Parts Call 608-268-8080