NVR-3000 OPERATION MANUAL & INSTALLATION MANUAL
NVR-3000 OM.E 20210412-02
10
for receiving. As soon as the signal disappears on CH16, the scanning between two channels will restore.
If a signal is detected on the additional channel during sampling, the transceiver will continue the sampling of
0.15s on CH16 every 2s when receiving on the additional channel. Whenever a signal is detected on CH16
during sampling, the transceiver will stay on CH16 for receiving, by ignoring the signal on the additional
channel.
Procedures:
①
Set the additional channel to be watched (for example CH18). Refer to Section 3.2
Channel Setting
.
②
Click
[MULIT]
-
[DW]
to start the scanning. The screen alternately switches between CH 16 and CH 18.
③
To stop scanning, click
[MULIT]
-
[DW]
again or click any other button on the screen.
2.4.2 All Channel Scan
In All Channel Scan, CH16 and all other channels will be scanned alternatively in a cycle of 0.15/1.8 seconds.
Click
[MULIT]
-
[SCAN]
to start the scanning of all channels cyclically, click again to stop the scanning.
Note: Transmitting is disabled during scanning.