2.2   Technical Data

IHN800

Voltage (± 9%):

3 ~ 400 – 575V / 50 – 60Hz*

Recommended circuit protection

63A circuit breaker

Power consumption (maximum)

24kVA

Temperature control

0 – 250°C (32 – 482°F) in steps of 1°C (2°F) 

Probe maximum temperature

250°C (482°F)

Time mode

0 – 60 minutes in steps of 0�1 minute

Power range

50 – 100%

Demagnetisation, automatic

Residual magnetism < 2A/cm

Overall dimensions

750 x 400 x 935mm

Area between supports (wxh)

330 x 355mm

Coil diameter

186mm

Weight (with yokes)

300kg

Workpiece maximum weight

1200kg

Maximum heating temperature

Approx� 400°C (752°F)

Standard yoke dimensions

100 x 100 x 570mm (for Ø of 142mm)

3  Installation of Mains Plug

Due to the many types of mains plugs, no mains plug is supplied with the IHN800� A qualified electrician must install a  
suitable mains plug� The correct supply voltage is shown on the type plate / underside of the heater�

The wires should be connected as follows:

Color of IHN800 Wire

Mains Supply Terminal

Yellow/green

Protection earth (PE)

Brown

Phase 1 (L1)

Blue

Phase 2 (L2)

Connect the IHN800 to only two of the three phases� Verify that the correct circuit breaker is installed� See section 2�2 for 
circuit breaker specifications�

*  Each bearing heater family has several voltage options. Please refer to the type plate on the heater body to determine the actual operating voltage.

Содержание IHN800

Страница 1: ...USER MANUAL INDUCTION HEATER IHN800 SUBSCRIBE TO NSK NEWSLETTER SUBSCRIBE TO NSK NEWSLETTER ...

Страница 2: ...nts 4 2 2 Technical Data 5 3 Installation of Mains Plug 5 4 Preparation for Use 6 5 Operation 7 5 1 Function of Displays 7 5 2 Function of Buttons 7 5 3 Temp Mode 8 5 4 Time Mode 8 5 5 Temperature Measurement 9 5 6 Change of Temperature Unit 9 5 7 Demagnetisation 9 5 8 Power Level Selection 9 6 Safety Features 10 7 Troubleshooting 10 8 Spare Parts 11 ...

Страница 3: ... heat resistant gloves to handle hot workpieces Safety Recommendations 1 Introduction The IHN800 induction heater is designed to heat bearings that are mounted with an interference fit onto a shaft The heat causes the bearing to expand which eliminates the need to use force during installation A 90 C 194 F temperature difference between the bearing and shaft is generally sufficient to enable insta...

Страница 4: ...ecause the heat is generated within the workpiece all of the heater components remain cool 2 Description The heating cycle is electronically controlled either in a TIME MODE where the heating time is selected or in a TEMP MODE where the desired temperature is selected The heater can further be run on 50 capacity when small yokes are used or when there is a risk for too quick heating of sensitive w...

Страница 5: ...andard yoke dimensions 100 x 100 x 570mm for Ø of 142mm 3 Installation of Mains Plug Due to the many types of mains plugs no mains plug is supplied with the IHN800 A qualified electrician must install a suitable mains plug The correct supply voltage is shown on the type plate underside of the heater The wires should be connected as follows Color of IHN800 Wire Mains Supply Terminal Yellow green Pr...

Страница 6: ... centre Remove the protective film from the bright underside of the sliding yoke before the first use Slide the sliding yoke to the right so that it completely covers the top of both vertical supports For workpieces that do not fit over the inductive coil these should be heated on the horizontal yoke If you will use TEMP MODE plug the temperature probe into the connector on the left side of the he...

Страница 7: ... C Temperature in degrees Celsuis F Temperature in degrees Fahrenheit 5 2 Function of Buttons Button Function POWER Control lamp for main switch on TIME TIME MODE TEMP TEMP MODE BEARING BEARING MODE recommended heating temperature for bearings of 110 C 230 F is automatically selected START STOP To start and stop heating ON OFF Press to start or stop the heater 50 Power reduced to 50 100 Full capac...

Страница 8: ... C 257 F must not be exceeded unless otherwise specified Press the 50 key to reduce the POWER to 50 Use the guidelines in section 5 8 to determine the correct power setting Press START STOP to start the heater The main display shows the current temperature of the workpiece When the selected temperature has been reached the heater demagnetises the workpiece switches off and generates an acoustic si...

Страница 9: ...sed when heating is complete Demagnetisation will not occur if the power is interrupted or the main switch is switched off To use the IHN800 for demagnetisation only select TIME MODE and set the time to 0 1 minute 6 seconds 5 8 Power Level Selection When heating bearings with an induction heater most of the heat will be generated in the inner bearing race The heat will then be transferred through ...

Страница 10: ...ibed in section 6 or operate the heater in TIME MODE E06 E Temperature probe not connected or defective Check the temperature probe E07 E Failure during current measurement Return heater for repair A system fault will be indicated by an acoustic signal and one of the following fault codes on the main display 6 Safety Features The IHN800 is equipped with the following safety features Main switch wi...

Страница 11: ...GLOVES Spare temperature probe for IHN800 IHNP1SENSOR Spare yoke 65 x 65 x 570mm for IHN800 IHN800 Y1 Spare yoke 100 x 100 x 570mm for IHN800 IHN800 Y2 Spare support yoke 100 x 100 x 150mm for IHN800 IHN800 YS1 Spare support yoke 100 x 100 x 370mm for IHN800 IHN800 YS2 ...

Страница 12: ...uartier de l Europe 2 rue Georges Guynemer 78283 Guyancourt Cedex Tel 33 0 1 30573939 Fax 33 0 1 30570001 info fr nsk com Germany Austria Switzerland Nordic NSK Deutschland GmbH Harkortstraße 15 40880 Ratingen Tel 49 0 2102 4810 Fax 49 0 2102 4812290 info de nsk com Italy NSK Italia S p A Via Garibaldi 215 20024 Garbagnate Milanese MI Tel 39 02 995 191 Fax 39 02 990 25 778 info it nsk com Poland C...

Отзывы: