5
2.2 Technical Data
IHN080
IHN0120
Voltage (± 9%):
1 ~ 100 – 240 V / 50-60 Hz*
3 ~ 400 – 575 V / 50-60 Hz*
Recommended circuit protection
20 A circuit breaker
20 A circuit breaker
Power consumption (maximum)
3�7 kVA
9�2 kVA
Temperature control
0 – 250 °C (32 – 482 °F)
in steps of 1 °C (2 °F)
0 – 250 °C (32 – 482 °F)
in steps of 1 °C (2 °F)
Probe maximum temperature
250 °C (482 °F)
250 °C (482 °F)
Time mode
0 – 60 minutes in steps of 0�1 minute
0 – 60 minutes in steps of 0�1 minute
Power range
20 – 100% in steps of 20%
20 – 100% in steps of 20%
Demagnetisation, automatic
Residual magnetism < 2 A/cm
Residual magnetism < 2 A/cm
Overall dimensions
420 x 280 x 345 mm
420 x 280 x 420 mm
Area between supports (wxh)
145 x 205 mm
145 x 205 mm
Coil diameter
115 mm
115 mm
Weight (with yokes)
35 kg
38 kg
Workpiece maximum weight
Bearing 80 kg, solid component 40 kg
Bearing 120 kg, solid component 60 kg
Maximum heating temperature
Approx� 400°C (752°F)
Approx� 400 °C (752 °F)
Standard yoke dimensions
55 x 55 x 275 mm (for Ø of 80 mm)
28 x 28 x 275 mm (for Ø of 40 mm)
14 x 14 x 275 mm (for Ø of 20 mm)
55 x 55 x 275 mm (for Ø of 80 mm)
28 x 28 x 275 mm (for Ø of 40 mm)
14 x 14 x 275 mm (for Ø of 20 mm)
3 Installation of Mains Plug
Due to the many types of mains plugs, no mains plug is supplied with the IHN080/120� A qualified electrician must install a
suitable mains plug� The correct supply voltage is shown on the type plate / underside of the heater�
The wires should be connected as follows:
IHN080
Color of IHN080 Wire
Mains Supply Terminal
Yellow/green
Protection earth (PE)
Brown
Phase 1 (L1)
Blue
Neutral (N)
* Each bearing heater family has several voltage options. Please refer to the type plate on the heater body to determine the actual operating voltage.