1
TABLE OF CONTENTS
Section Page
Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . .1
At Power Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.0 Clock Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.0 Clock Set Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.0 Date Set Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
4.0 Daylight Saving Time . . . . . . . . . . . . . . . . . . . . . . . . . . .2
4.1 To Modify Daylight Saving Time . . . . . . . . . . . . . . . . . . .3
5.0 Holiday Dates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.1 To Set Holiday Dates. . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.0 Schedule Set Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.1 Setting Hours, Minutes, and Days . . . . . . . . . . . . . . . . . .5
7.0 Review, Modify, and Delete. . . . . . . . . . . . . . . . . . . . . . .7
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Schedule Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
TORK MODELS DG100A / DGM100A / DG200A
7 DAY DIGITAL TIME SWITCH
READ INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL TIME SWITCH. SEE
WARNING ON FRONT PANEL
– Failure to comply with
instructions could result in personal injury and/or property
damage.
INSTALLATION:
UNIT IS TO BE INSTALLED BY A LICENSED ELECTRICIAN
1. Remove unit from enclosure by pushing the inside tab
(located near the outside hasp) to the right. Swing unit
to left and remove.
2. Mount the enclosure at eye level using screws or other
suitable fastening device. Bring supply and load wires
in through or side knockouts. DO NOT USE TOP.
3. Reinstall unit by reversing step #1 above and connect-
ing wires to units as per suggested wiring diagrams at
back of manual.
4. Unit should be programmed with AC power. Do not
program under super cap back up power.
AT POWER UP:
Connect unit to main power source prior to entering the
settings. When powering up the unit for the first time, allow
1-2 minutes for super cap to charge and the display will
show 12 HOUR. Press reset button after 2 minutes if screen
is blank.
CAPABILITIES:
• 7 day scheduling.
• 56 set points
• 9 Block holidays
FEATURES:
Daylight Saving
- Automatic (user selectable).
Leap Year
- Automatic compensation.
Power Outage
- Permanent schedule retention. Supercapaci-
tor provides 7 days of real time backup.
Manual Override
- Until the next scheduled event.
AM/PM or 24 Hour Format
- user selectable
Multi-Voltage Input
- Permanent schedule retention. Superca-
pacitor maintains real time up to 4 days.