![NSFOCUS ADS NX3 10000 Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/nsfocus/ads-nx3-10000-series/ads-nx3-10000-series_installation-manual_1714409032.webp)
NSFOCUS ADS Installation Guide
Copyright © NSFOCUS
26
V4.5R90F01SP07C236 (2019-11-19)
Step 4
Turn the power switch to 1 (or pull the power switch of each board to the left for ADS NX5-
10000) to turn on the power module.
On ADS NX5-10000, the power switch, after being pulled left, will immediately flip
back to the original position.
Step 5
Check the status of the power LED on the front panel of the ADS device.
For details on the power LED and status LED, see
----End
3.3
Connecting to the Network
Connect the ADS device to the network according to the actual network architecture.
Pay attention to the following:
Use straight-through cables to connect the switch to the communication interface of the
device.
The ADS device can be deployed anywhere in the network. However, to achieve the
optimal performance, you are advised to connect it to the switch on the backbone
network of the intranet.
After deployment, please adapt network settings immediately to the actual network
environment. For details on default parameters of the ADS device, see appendix
You can modify network settings at either the console management interface or web-
based manager (see chapter
3.4
Shutting Down the Device
For ADS NX3-2020/2020E/2010, NX5-4020/4020E, NX5-6025/6025E, NX3-
HD2500/NX5-HD4500/6500, NX3-200E/600E/800E, and NX5-8000, you can turn the
power switch to 0 to shut down the device.
For ADS NX5-10000, you need to pull the power switch to the left and hold it for at least
4 seconds to shut down the device. The entire system can be shut down only after the
power switch of each service board is turned off. After ADS is shut down, you can pull