Copyright Harmsco
®
Inc.
All rights reserved.
1243-HP, MANUAL - HUR FL
Page 4 of 25
HARMSCO
®
Hurricane
®
Swing Bolt Water Filters
REQUIREMENTS
●
Only qualified personnel are to perform the installation.
●
Flush unit (through outlet) to drain for 10 minutes at recommended flow
rates
prior
to
use.
●
Install shut off valves on both the inlet and the outlet to isolate unit
while
servicing.
RECOMMENDATIONS
●
Plumb drains with appropriate valves to reduce service time.
●
Include a by-pass with shut off valves between the inlet and outlet.
See installation Block Diagram on page 7.
●
Install appropriate pressure gauges into the gauge ports provided.
Model
HUR1X170FL
outlet
pressure
gauge is to be installed in-line
and in close proximity to the outlet flange.
●
Install plug or appropriate valve into the vent port provided.
●
Lubricate Swing Bolt Assemblies (all models) & Davit Assemblies
(HUR 3X170FL, HUR 5X170FL & HUR 8X170FL) using Food Grade
grease with PTFE and NSF rated H1 only.
●
Replace cartridge(s) when certain conditions exist.
For
example:
1.
Differential pressure is greater than 30 psi.
2.
Quality
of
water
is
unacceptable.
3.
Flow
rate
has
diminished.
4.
Every
6
months
●
Spare Parts:
1. Sufficient supply of replacement cartridges.
Note: Harmsco
®
Hurricane
®
HC/170 filter cartridges available
include: Activated Carbon, High Temperature, SureSafe
TM
,
Poly-Mesh, Poly-Pleat
TM
& more.
Contact
a
Harmsco
®
sales representative for Harmsco
®
Hurricane
®
HC/170 filter cartridge specifications.
2.
Housing
O-ring
Seal:
Model # Part #
EPDM
(std)
BunaN Viton
HUR
1X170FL
361-E 361-B
361-V
HUR
3X170FL
363-E 363-B
363-V
HUR
5X170FL
365-E 365-B
365-V
HUR
8X170FL
368-E 368-B
368-V
3.
Optional:
Cartridge
Lifting Handle, Part #362-L