7.3 Brake Adjustment
·
There are two brake adjusters on each side of the Rollator, one in front of the brake handle
and the second is positioned in the middle of the brake cable (See diagram 6)
·
To adjust the handle brake, loosen the lock nut, turn the adjuster anticlockwise to tighten
the brake then retighten the lock nut. (See Diagram 5)
·
To adjust the mid-cable brake, loosen the lock nut, turn the adjuster anticlockwise to tighten
the brake then retighten the lock nut. (See Diagram 6)
·
For correct adjustment the brake mechanism should not touch the wheel, but the gap
should be no greater than 3mm.
·
Caution: After making any adjustments to the brakes, you must test them before the rollator
is used.
·
If adjustment does not tighten the brakes, do not use the rollator. Contact your dealer or
NRS Customer services, details below.
2 - Turn Adjuster
(Anti-clockwise to
tighten brake)
1 - Loosen Lock Nut
3- Re-tighten Lock Nut
DIAGRAM: 5
2 - Turn Adjuster
(Anti clockwise to
tighten brake)
DIAGRAM: 6
1 - Loosen Lock Nut
3- Re-tighten Lock Nut