17
National Rejectors, Inc. GmbH, Buxtehude
G-13.6 Description of the variants
Switch 7
Switch 8
Pulse frequency (pulse-pause relation)
down
down
20 msec. pulse /80 msec. pause
up
down
50 msec. pulse /200 msec. pause
down
up
100 msec. pulse /400 msec. pause
up
up
200 msec. pulse /800 msec. pause
e.g.:
lowest coin = 0.10 DM / adjusted value = 10 (2 + 8)
∅
price = 1.00 DM
pulse-pause relation = 20 msec. pulse / 80 msec. pause
Fig. 6: Adjusting the price and the pulse frequency
By means of the second switch arrangement the discounts can be
adjusted for those types of coins that are indicated on the label of the
totalizer. This is done by means of four switches that serve to enter the
pulse number (0 - 15).
e.g.:
pulse number for coin A = 3 / pulse number for coin B = 7
Fig. 7: Adjusting the pulse number
1
1
2
2
3
4
4
8
Switch block 1
5
16
6
32
7
pulse length
8
ON
OFF
Value
1
1
2
2
3
4
4
8
2
4
8
Switch block 2
5
1
6
7
8
ON
OFF
Value