30
National Rejectors, Inc. GmbH, Buxtehude
M
AINTENANCE
AND
SERVICE
7
Maintenance and service
In this chapter you will find out how to
•
clean the hopper, and
•
remedy the cause of a malfunction.
Please pull out the machine’s mains plug before you clean or
maintain the hopper.
Cleaning hopper (every six month)
The coins may leave residues on sensitive parts of the payout unit, when
they are transported. These residues must be removed from time to time,
in order to guarantee a reliable hopper operation:
•
Cleaning interval: every 500,000 payouts/six month
•
Cleaning agent:
ethyl alcohol 96 %, cotton bud/brush (with fine
fibres, never metal), cloth
Do not use any solvents or scouring agents which attack the
plastic of the device.
Do not submerge the hopper in any kind of liquid. This will
damage the device.
1
Pull the machine's mains plug.
2
Pull the locking pin [12a/1] of the safety
flap [12a/2] inwards and fold the flap
upwards.
2
1
Fig. 12a: Folding safety flap upwards