Symphonie_Sensor_Connections_Instructions | Rev 2.0 | 23 February 2015 |
|| 2
Default Slope and Offsets for Symphonie
Both the Symphonie logger and SDR software come loaded with default slope and offset values for our standard
sensors. Please note that these settings are specific to Symphonie and may not be the same values used for
other data loggers. Some sensors are provided with sensor specific values that may be used in place of these
defaults.
Sensor Default Slope and Offsets for use with Symphonie
Sensor
Slope
Offset
Scaled Units
NRG #40 Anemometer
0.765
0.35
m/s
NRG #200P Wind Direction Vane
0.351
0
degrees
NRG #110S Temperature Sensor with Radiation
Shield
0.136
-86.38
C
NRG #BP20 Barometric Pressure Sensor
0.4255
650
mB
Relative Humidity Sensor
0.097
0
%RH
Li-Cor #LI-200SA Pyranometer
1.32
0
W/sqm
Rain Gauge-Tipping Bucket
0.254
0
mm
***iPack Voltmeter SCM***
0.021
0
Volts