background image

 

Symphonie_Sensor_Connections_Instructions     |     Rev 2.0     |     23 February 2015    |     

[email protected]

     ||     2 

 
Default Slope and Offsets for Symphonie  

Both the Symphonie logger and SDR software come loaded with default slope and offset values for our standard 
sensors.  Please note that these settings are specific to Symphonie and may not be the same values used for 
other data loggers.  Some sensors are provided with sensor specific values that may be used in place of these 
defaults.   
 
 

Sensor Default Slope and Offsets for use with Symphonie 

Sensor 

Slope 

Offset 

Scaled Units 

NRG #40 Anemometer 

0.765 

0.35 

m/s 

NRG #200P Wind Direction Vane 

0.351 

degrees 

NRG #110S Temperature Sensor with Radiation 

Shield 

0.136 

-86.38 

NRG #BP20 Barometric Pressure Sensor 

0.4255 

650 

mB 

Relative Humidity Sensor 

0.097 

%RH 

Li-Cor #LI-200SA Pyranometer 

1.32 

W/sqm 

Rain Gauge-Tipping Bucket 

0.254 

mm 

***iPack Voltmeter SCM*** 

0.021 

Volts 