background image

2000 Cycles Maintenance Counter - Alarm

Once the operator has reached 2,000 cycles, the built in alarm will sound and the courtesy light 

will flash. The alarm and lights will continue to flash until cancelled. This serves as a reminder to 

the user to carry out the annual maintenance inspection and service.

To cancel the alarm do one of the following:

1.  Press and button on the transmitter for 3 seconds

2.  Press P button for 5 seconds (installer only)

3.  Power off, then on the operator

To activate or de-activate the cycle alarm:

1.  Press P button for 5 seconds, LED 1,2 & 3 are illuminated

2.  Press + five times, LED 1, 2 & 3 flash

3.  Press + to check the status of the alarm setting

4.  Press + or - to toggle between alarm on or off.

5.  Press P button to confirm setting. 

 

 LED 

Status    Meaning

 

LED1 Flashes once every 3 seconds 

 

Alarm ON

 

LED 1 Flashes twice every 3 seconds   

Alarm OFF

Programming 2000 Cycles Counter Alarm

Содержание Black Edition

Страница 1: ...AUTOMATIC ENTRANCE SOLUTIONS WARNING Please start by reading the safety instructions garage door operator BLaCKeDITION Installation Guide 022015BEGDO Nrg Automation Range 2015 16 ...

Страница 2: ...Control Board Wiring 4 Installing the Boom Operator 5 Programming Motor Limits Force Settings 6 Programming Alarm Auto Time Closing 7 Programming Reversing Force 8 Programming 2000 Cycles Maintenance Alarm 9 Programming Transmitters 10 www nrgautomation co uk Contents ...

Страница 3: ... with protection class 2 and does not require earthing Once installed the auto reverse system should undergo a test upon contact with a 50mm solid object from the ground the garage door should stop and then re open Warning signs should be used to warn of door opening and closing Do not allow children or untrained users access to the controls including radio controls Always watch a moving door keep...

Страница 4: ...r arm fixing bracket 8 Above door boom bracket 9 Various fixings screws Boom Package 1 One piece or three piece boom 2 Carrier with cord release 3 Motor drive adapter 4 Two slide over brackets 3 piece boom only Remove the programming cover to reveal the programming buttons and LED s Parts Lists Only required for booms over 3300 mm or 3 piece booms ...

Страница 5: ...ds on the size of the batteries A two piece battery pack with 7 amps 24vdc can provide approximately 40 complete cycles A single battery of 7 amps would provide enough power for approximately 30 cycles 1 2 3 4 5 6 7 8 9 Terminal Wiring 1 Photocell 24V Brown 2 Photocell Black N C 3 Photocell 24V Blue White 4 Switch connection COM 5 Switch Connection N O 6 LED light strip 24vdc 7 LED light strip 24v...

Страница 6: ... the mid point only for booms longer than 3300mm or 3 piece booms 4 Using the metal mounting strap and U bracket secure the boom to the ceiling at the motor end Attaching the Motor to Boom 1 Insert the splined BRASS expander joint into the carrier drive system may be installed already 2 Offer the motor to the Boom inserting the drive into the BRASS expander drive joint 3 Using the two U type brack...

Страница 7: ...tton to save OPEN limit position LED 1 will go out and LED 2 will flash to enter CLOSE limit setting Step 2 Close Limit 1 Press and hold button to close the door to the desired close position before releasing 2 Press P button to save the DOWN limit position 3 LED 2 will go out LED 3 will flash to enter FORCE learning program Step 3 Force Learning 1 Press button and the door will open automatically...

Страница 8: ... 8 times every 3 seconds 240 seconds If auto time close is selected before the door starts to close the courtesy light will flash for 20 seconds When the door starts to close the courtesy light remains on and remains on for 3 minutes Alarm Programming 1 Press P button for 5 seconds LED s 1 2 3 illuminate 2 Press button 3 times LED 2 3 flash 3 Press to check the status of the Alarm i e on or off 4 ...

Страница 9: ...sed by trained professional Installers Force reversing Programming Professional installers ONLY If the garage door will not fully close and the operator requires more force to close please get in touch with our technical department We advise that ONLY professional installers adjust the force level setting If a level above 2 is required we would suggest additional safety devices are fitted and that...

Страница 10: ...ng 1 Press and button on the transmitter for 3 seconds 2 Press P button for 5 seconds installer only 3 Power off then on the operator To activate or de activate the cycle alarm 1 Press P button for 5 seconds LED 1 2 3 are illuminated 2 Press five times LED 1 2 3 flash 3 Press to check the status of the alarm setting 4 Press or to toggle between alarm on or off 5 Press P button to confirm setting L...

Страница 11: ...e on another button 1 Press hold S button for 2 seconds LED1 illuminates 2 Press top or top left button TWICE LED1 turns off 3 Press hold again S button for 2 seconds LED1 illuminates 4 Press next channel on transmitter TWICE LED1 turns off Mode 3 Lights On and Off using a spare channel 1 Press hold S button for 2 seconds then press 3 more times the S button LED1 illuminates 2 Press the spare chan...

Страница 12: ...ation co uk Nrg Automation Range 2015 16 AUTOMATIC ENTRANCE SOLUTIONS Garage Door Automation Solutions Single Piece Garage Doors Sectional Garage Doors Roller Garage Doors Radio Controls Smart Phone and GSM Control ...

Отзывы: