background image

Page 1 

 

 

 

 

 

 

 

 

 

 

      INST2021 – 6/14 

1. 

Introduction 

 
Since 1969, NRD has produced ionizing radioactive sources that are used in static control, smoke 
detectors, physics research, space exploration, and instrumentation.  NRD is the world’s largest 
and one of the oldest suppliers of radioactive metallic foils.  Specially designed equipment and 
facilities  enable  us  to  produce  a  sealed  source  device  that  is  safe  and  is  highly  effective  in 
eliminating static. 
 
 
1.1 

Our Thanks 

 
Thank you for choosing NRD for your static control needs.  You have chosen a highly effective 
static  eliminator  device  that  is  reliable,  requires  no  calibration,  and  is  safe.    Please  review  the 
information in this manual to maximize the benefit of NRD’s In-Line Ionizers. 
 
 
1.2 

Other NRD Products 

 
NRD offers static eliminator devices and accessories to eliminate or control electrostatic charges.  
The many product configurations we offer will fit a wide field of applications.  Just call us with 
your application and we can provide a solution. 
 
The  electronics  industry  uses  air  ionizers  to  reduce  product  damage  and  loss.    Application  of 
ionizers in the printing, converting and graphics industries allow in-process cleaning of product 
and  faster  process  speeds.    Higher  productivity,  better  quality,  and  enhanced  reliability  help 
make your company a success. 
 
Here is the range of products we offer: 
 

 

Nuclestat

®

 Bars

 offered in lengths of 4” to 142”. 

 

Nuclecel

 

In-Line Ionizers

 for parts blow-off and surface preparations. 

 

Nuclespot

 Ionizer provides focused concentration of ions to the product.  

 

Tabletop 

Blowers

 for electronic assembly. 

 
Detailed  data  sheets  and  informational  notes  are  available  upon  request.    Consult  the  main 
catalog for listing. 
 
 
 
1.3 

Customer Support 

 
Toll Free Number 

1-800-525-8076 

 

8:30 AM – 5:00 PM Eastern Time (M-F) 

General Listing 

1-716-773-7634 

Fax Number   

1-716-773-7744 

 
 

Содержание Staticmaster P-2021 Series

Страница 1: ... Series Ionizers CONTENTS 1 0 Introduction Page 1 1 1 Our Thanks 1 2 Other NRD Products 1 3 Customer Support 2 0 General Information Page 2 2 1 Safety of NRD Devices 2 2 Lease Agreement 2 3 Return of Expired Devices 3 0 In Line Ionizers Page 3 4 0 Accessories Page 4 4 1 Gun Handles 5 0 Maintenance Troubleshooting Page 5 APPENDIX Assembly Installation of In Line Ionizers Page 6 Specifications Safet...

Страница 2: ...r control electrostatic charges The many product configurations we offer will fit a wide field of applications Just call us with your application and we can provide a solution The electronics industry uses air ionizers to reduce product damage and loss Application of ionizers in the printing converting and graphics industries allow in process cleaning of product and faster process speeds Higher pr...

Страница 3: ...surface provided on the cell Do not alter the ionizer in any way i e drilling holes Review the enclosed Safety Brochure for a more detailed description of how the ionizers work where they are typically used and the general safety of NRD ionizers 2 2 Lease Agreement All ionizers containing Polonium 210 are leased not purchased The devices are leased for two main reasons 1 Federal Regulations state ...

Страница 4: ...ptional Adapters Note Ensure that the gas supply is properly filtered and that attached hoses are clean and dry Inquire about filter options The gas can be air or an inert gas such as nitrogen B Attach the ionizer to the hose fitting and tighten securely An O ring is provided on the threaded end of the cell to seal the connection If the parts become loosened apply a small amount of removable adhes...

Страница 5: ...n Note Ensure that the air supply is appropriately filtered and that attached hoses are clean and dry Inquire about filter options D Attach the gun to the 1 4 NPT hose fitting by screwing the base of the handle securely into the fitting Use teflon tape as needed E Set pressure to 40 psig first to determine if this supplies sufficient air volume and pressure to remove static and debris from surface...

Страница 6: ...ll to NRD for evaluation Do not attempt to clean the device Ions generated are being recombined before they reach the charged surface The Ionizer air exit needs to be closer to the charged surface 2 Air flow is reduced Upstream filter s are plugged and or gas pressure is low Replace upstream filter s and or increase gas pressure 100 psig max 3 Squeezing gun handle trigger does not initiate gas flo...

Страница 7: ...Page 6 INST2021 6 14 ASSEMBLY INSTALLATION IN LINE IONIZERS General Purpose Gun Ionizers Cleanroom Gun Ionizer ...

Страница 8: ...Page 7 INST2021 6 14 ...

Страница 9: ...Page 8 INST2021 6 14 ...

Страница 10: ...Page 9 INST2021 6 14 ...

Страница 11: ...Page 10 INST2021 6 14 ...

Страница 12: ...Page 11 INST2021 6 14 ...

Отзывы: