background image

INST6200 – 4/04 

Installation / Operation / Maintenance 

Staticmaster

®

 

Model 6200HOB    Ionizing Air Blower 

 

Another example would be neutralizing plastic 
parts as they exit a plastic injection mold and are 
conveyed to a container.  Keeping parts 
neutralized through this process will prevent them 
from re-attracting to the mold cavity; prevent them 
from attracting air borne contamination; allow 
them to fall freely from the conveyor and into the 
container, and prevent annoying, uncomfortable, 
shocks to operators. 

 
 
 

To Achieve Best Results 

 

 

The Staticmaster

®

 6200HOB must be properly 

grounded.  It comes equipped with a UL-approved 
detachable line cord with a three-prong plug on 
one end and a three-prong receptacle on the other 
end.  It is essential to the performance of the 
Staticmaster

®

 6200HOB and to the safety of the 

operator that the third prong (ground) never be 
removed and that the three-prong plug be inserted 
only into a known, properly wired and grounded 
three-prong receptacle. 

 

Metal or other conductive materials (too close 
to the material to be neutralized) act as a sink 
for static neutralizing ions stealing them from 
the electrostatically charged material for which 
they are intended.  Be sure that the material to 
be neutralized is not in contact with another 

        surface.  Direct the ionized air toward the material 

      or parts just before or just after they come in 
      contact with a background surface.  As much as 
      possible, the material or parts should be in free 
      air to achieve maximum neutralizing results 
      from Ionizers. 

 

The Staticmaster

®

 6200HOB is an extended 

range air ionizer.  It is capable of neutralizing 
electrostatically charged materials as distant as 
ten feet.  However, the closer it is to the charged 
material, the faster the charge will be neutralized.  
If the charged parts are stationary, and the length 
of time required to neutralize them is of no 
consequence, then the Staticmaster

®

 6200HOB 

could be sufficiently effective mounted at a 
distance of ten feet from the material.  If the 
material were passing by the ionizer at 1000 feet 
per minute, then it would be virtually ineffective 
from ten feet.  On average, the most effective 
range for the Staticmaster

®

 6200HOB is within 

two feet. 

 

The Staticmaster

®

 6200HOB will operate 

efficiently above, below, or on either side of the 
material.  Keeping the ionizing points facing 
downward will minimize contamination and 
falling foreign matter from collecting on them. 

 

A universal bracket and mounting hardware is 
provided with the Staticmaster

®

 6200HOB. 

 

Содержание Staticmaster 6200HOB

Страница 1: ...e environment In most applications a quick brushing or blow out with a compressed air gun once each month is adequate Installation Initial set up and Positioning Proper location and positioning of the Staticmaster 6200HOB is essential to satisfactory performance and to the life of the equipment Because each application is somewhat unique careful thought should be given to establish the best locati...

Страница 2: ...ed material for which they are intended Be sure that the material to be neutralized is not in contact with another surface Direct the ionized air toward the material or parts just before or just after they come in contact with a background surface As much as possible the material or parts should be in free air to achieve maximum neutralizing results from Ionizers The Staticmaster 6200HOB is an ext...

Страница 3: ...ompressed air blow off gun will keep the Staticmaster 6200HOB performing at peak efficiency Usually in the average manufacturing environment a quick once a month cleaning is sufficient more often in a dirty environment less often in a clean one Do not use a brush with metal bristles Shedding metal bristles trapped in the unit s circuitry will lead to a short circuit condition and ultimate failure ...

Страница 4: ...es not significantly reduce or eliminate the problem after it has been properly installed please check the following Is the female end of the line cord properly secured into the receptacle on the Staticmaster 6200HOB Is the fuse OK It is located on the receptacle at the female end of the line cord Is the three prong male end plugged securely into a proper mating receptacle with ground Is there con...