2.0
Accessories
2.1
Model 4067 Staticmaster
Small Ionizing Fan
The Model 4067 is used to create airflow through the Ionizer (model P-2062). This system
delivers a high volume of ionized air to reduce charge on parts. The Fan is mounted on a swivel
base and can be placed on a flat surface or bolted to a rigid surface.
Procedure to install a new P-2062 Ionizer:
A.
Unplug AC adapter from the electrical outlet.
B.
Remove two (2) thumb screws.
C.
Slide the model P-2062 into opening in middle plate; make sure holes in the P-2062 cell align
with the pins protruding through middle plate.
D.
Replace back cover.
E.
Secure back cover and model P-2062 ion cell in place with the two (2) thumb screws
removed in step 2.
F.
Connect the AC adapter to a 120 VAC, 60 Hz electrical outlet.