4-3. Filter Cover Cleaning
Remove filter cover from top panel of main enclosure.
Clean filter cover with water or compressed air.
After cleaning, make sure ionizer is dry before turning power on.
If there is any damage on the filter cover, it is recommended to replace it.
4-4. Emitter Point Replacement
Remove filter cover from top panel of main enclosure.
Remove emitter points from sockets by gently pulling out toward the middle of the ionizer.
Caution
,
emitter points are very sharp, using tweezers or pliers is acceptable.
Insert new emitter points into sockets by gently pushing in as far as it will go.
Caution
, emitter points are
very sharp, using tweezers or pliers is acceptable.
NOTE: Emitter point useful life also varies based on operating environment and use. Recommended
replacement interval is once a year to once every other year.
5. Specification
Input Voltage
110 ~ 240V AC
Ion Emission
Steady-State DC Technology
Balance
< ±20V
Discharge
less than 2 seconds per ANSI/ESD STM3.1
3 Step Fan Speed Adjustment
Air flow
27 ~ 100 CFM
Emitter Point
Tungsten 99.99%
Alarm Function
Audio/LED Alarm at HV Power failure
Output Monitoring
FMS Interface
Material
ABS for Ionizer Enclosures and Brackets
Operating Environment Temperature: 15~35
℃
Relative
Humidity: 35~75%
Dimensions (W×H×D)
4.7” x 7.1” x 39.4” (118×180×1000 mm)
Weight
7.9 lbs. (3.6 kg)