3. FMS Connection 

3-1 . Interface Terminal Connection 

Pin No. 

Description 

 

Facility Monitoring System Output Signal 

FMS 1   Alarm signal relay output 

   Condition 

FMS 1~2 

FMS 4~5 

FMS 3~6 

FMS 2   Alarm relay common 

   Normal state 

Open 

4~5mA 

Open 

FMS 3   Out of balance signal relay output     Alarm State 

Closed 

17~20mA 

Closed 

FMS 4   Current output for each operation 

   No Power 

Closed 

0mA 

Closed 

FMS 5   Reference ground for current output     

 

 

 

FMS 6   Out of balance relay common 

   

 

 

 

 
3-2. Interface Terminal Cabling 

  

   

 
 
 
4. Maintenance 

NOTE: Turn power off prior to doing regular maintenance or emitter point cleaning. 

4-1. Filter Cover Attach and Release 

 

Press down, on tabs, at the top of the filter cover and release or attach it on the main enclosure. 

                         

 

 

4-2. Emitter Point Cleaning 

 

Remove filter cover from top panel of main enclosure. 

 

Clean emitter points using cotton swab with DI water or Isopropyl Alcohol.

 Caution

, emitter points are 

very sharp. 

 

After cleaning, make sure ionizer is dry before turning power on. 

 

If there is any damage or excessive wear on the emitter point, it is recommended to replace it. 

NOTE: Cleaning requirements of emitter points will vary based on operating environment and use. 
Recommended cleaning interval is once a month to once every other month. 

Содержание Corona Staticmaster 6220

Страница 1: ...08 90 CT Hub 2 Singapore 338729 PHONE 65 6679 1707 EMAIL sales NRDasia com WEB www nrdllc com 1 INST6220_05 18 Installation Operation Maintenance Corona Staticmaster Overhead Ionizing Fan Model 6220 Auto Balanced Ionization System Contents Precautions 1 Features and Descriptions 2 Installation 3 FMS Connection 4 Maintenance 5 Specifications 6 Dimensions 7 Warranty 2 2 3 4 4 5 6 6 ...

Страница 2: ...used by manufacturers for electronic industry applications and generates high voltage Do not open and modify it or operate without being completely assembled High voltage internal parts can cause electrical shock WARNING Before performing maintenance turn the Staticmaster off disconnect from the power source and do not wear a wrist strap High voltage internal parts can cause electrical shock WARNI...

Страница 3: ...eed 2 LEDs Medium speed 3 LEDs High speed 7 IR Receiver for optional Remote Control 8 LED Indicator for Operation and Alarm 9 Fan Filter Grill 10 Fan Filter Grill Hook 11 Fan Operation Sensor Hole 2 Installation 2 1 Locate the Staticmaster 12 300mm to 48 1200mm from the target to be neutralized for optimal performance making sure that the airflow will not be restricted A working electrical outlet ...

Страница 4: ... Closed FMS 5 Reference ground for current output FMS 6 Out of balance relay common 3 2 Interface Terminal Cabling 4 Maintenance NOTE Turn power off prior to doing regular maintenance or emitter point cleaning 4 1 Filter Cover Attach and Release Press down on tabs at the top of the filter cover and release or attach it on the main enclosure 4 2 Emitter Point Cleaning Remove filter cover from top p...

Страница 5: ... the middle of the ionizer Caution emitter points are very sharp using tweezers or pliers is acceptable Insert new emitter points into sockets by gently pushing in as far as it will go Caution emitter points are very sharp using tweezers or pliers is acceptable NOTE Emitter point useful life also varies based on operating environment and use Recommended replacement interval is once a year to once ...

Страница 6: ...y Call Customer Service at 716 773 7634 for a Return Authorization number and shipping instructions Include a copy of your original packing slip invoice or other proof of purchase date If the ionizer is out of warranty NRD LLC will quote repair charges necessary to bring your ionizer up to factory standards Warranty Exclusions The forgoing express warranty is made in lieu of all other product warr...

Отзывы: