background image

IMPORTANT: For safe and optimum performance, Jump Starter must be used properly. 
Carefully read and follow all instructions and guidelines in this manual and give special 
attention to the 

CAUTION

 and 

WARNING

 statements.

Please keep this manual for future reference.

       

WARNING 

Battery Leakage/Seeping : Unit must be stored upright or else some batteries will 
leak and cause damage not covered by the manufacturer.

Model number-24928

OWNER’S MANUAL

450W FLEX   POWERPACK XL 

 

Содержание 450W FLEX

Страница 1: ...lines in this manual and give special attention to the CAUTION and WARNING statements Please keep this manual for future reference WARNING Battery Leakage Seeping Unit must be stored upright or else s...

Страница 2: ...f life CAUTION Cautions identify conditions or practices that could result in damage to the unit or to other equipment NOTE These notes describe an important action item or an item that you must pay a...

Страница 3: ...s Included 3 Battery Choices Available 4 Installing the Battery 5 Specifications 6 Important Safety Instructions 7 Features 8 Operations 9 Recharging the Powerpack Battery 10 Troubleshooting 11 Warran...

Страница 4: ...erpack with jumpstart cables It is the main body of the unit the unit is without the battery 2 AC charging adapter It can recharge the unit from a standard AC wall outlet and it can only be used to re...

Страница 5: ...Procedures 1 Turn ALL Jumpstart AC USB and Compressor switches to OFF position 2 Unscrew the back cover of the powerpack 3 Lay down the powerpack a flat surface and put in your choice of battery U1 U1...

Страница 6: ...ed sine wave No load current draw 0 3A Input voltage range 10 5V 15 5VDC Low battery alarm 11 0 0 3V DC Low battery shutdown 10 5 0 3VDC High battery voltage shutdown 15 5V 0 3VDC Over temperature shu...

Страница 7: ...et DC Powerpack Socket Jumpstart Cable Port the ventilation holes do not expose this product to water rain snow condensation or spray WARNING Explosion Hazard Do not use this product near flammable fu...

Страница 8: ...to cool down for at least 3 minutes after each jumpstart WARNING Risk of Explosion Fire or Burns The battery terminals exposed at the Jumpstart Cable Port have enough energy present to cause a spark...

Страница 9: ...battery first Make sure all accessories are off so you don t cause an arc 7 Someone should be within range of your voice or close enough to come to your aid when you work near batteries 8 Have plenty...

Страница 10: ...th the powerpack contact the equipment manufacturer to determine the rechargeable appliance s compatibility with the modified sine wave non sinusoidal AC waveform Attention Charge Before Use Charge th...

Страница 11: ...ght Red yellow and one green LED light Red yellow and two green LED all light Note It is recommended that you should check the battery voltage after 30 minutes charging 7 Battery capacity button When...

Страница 12: ...r the cigarette plug 14 Jumpstart power switch manual rotary switch When jumpstarting a vehicle turn off the switch and the vehicle engine connect the unit to the vehicle then you can turn on the swit...

Страница 13: ...C charger Input voltage 110V AC Output voltage 13 5V DC Input current 0 5A Note it is recommended that you use the AC to DC adapter to charge the battery 22 Reverse polarity indicator battery terminal...

Страница 14: ...s These gases are very corrosive and prolonged exposure will damage the Mobile Booster Pack Protected from battery gases AC Appliance The Powerpack has one AC power outlet for use with AC appliance Yo...

Страница 15: ...ll do a complete shutdown automatically High surge appliance The wattage rating of AC appliance is the average power used by the appliance Appliances such as televisions computer monitors and applianc...

Страница 16: ...al operating time will be based on the actual DC appliances using wattage Operating DC Appliance 1 Check battery status to ensure the battery is fully charged 2 Open the DC socket USB port cover 3 Plu...

Страница 17: ...to be started Ensure that the Powerpack s jumpstart power switch is OFF 3 Connect the red positive clamp of the cables to the positive terminal of the engine battery 4 Connect the black negative clamp...

Страница 18: ...ow the compressor to cool for 15 minutes before re starting If the power switch is not turned off the compressor will automatically turn itself on when it reaches an acceptable operating temperature I...

Страница 19: ...attresses transport truck tires and inflatable boats These types of products require extended inflating times which may damage the compressor To inflate small sports equipment 1 Choose the appropriate...

Страница 20: ...ged every 3 months To recharge with AC charger 1 Turn the rotary switch to the OFF position 2 Plug 110V AC charger into charger input socket on the front of the unit 3 Plug 110V AC charger into 110V A...

Страница 21: ...e stereo systems and AM FM radios have inadequate internal power supply filtering and buzz slightly when powered by the powerpack Generally the only solution is an audio product with a higher quality...

Страница 22: ...lace the AC charger Internal battery is permanently damaged The charging status LED indicator still lights red and has not charged to steady after 50 hours of charging Replace the battery Charge it fo...

Страница 23: ...compressor hose for any breaks or leaks at connections Problem Cause Solution Battery has discharged to 11V The AC appliance does not operate audible alarm is sounding Recharge the battery Inverter ha...

Страница 24: ...d from improper use NPower will repair or replace the defective product free of charge Proof of purchase is required Warranty term is not extended if NPower repairs or replaces a product NPower owns a...

Отзывы: