background image

OLS Series Light Sources,

OPM Series Optical Power Meters,

and Related Test Kits

User’s Guide

www.AFLglobal.com/go/NOYES or 1-800-321-5298/1-603-528-7780

Noyes OLS 1 OLS 2 OPM 5 Specs

Provided by www.AAATesters.com

Содержание AFL OLS1D

Страница 1: ...ries Light Sources OPM Series Optical Power Meters and Related Test Kits User s Guide www AFLglobal com go NOYES or 1 800 321 5298 1 603 528 7780 Noyes OLS 1 OLS 2 OPM 5 Specs Provided by www AAATeste...

Страница 2: ...as been compromised or which have been subject to misuse negligence or accident In no case shall AFL liabilities exceed the original purchase price Exclusions The warranty on your equipment shall not...

Страница 3: ...lect Current File 14 File Manager To Select Current Fiber 14 Test Mode To Set Reference 14 Test Mode To View Reference 15 Recall Mode To View Stored Records 16 To Edit Stored Records 17 Clear Mode To...

Страница 4: ...wiring exposed or shorted contact the manufacturer to request servicing WARNING Use only the specified AC adapter Use of another type of AC adapter can damage the instrument and create the danger of...

Страница 5: ...A test jumper must have the same core and cladding size as the fiber under test The connector at one end of the test jumper must mate with the optical port on each instrument The connector on the oth...

Страница 6: ...calibrated wavelengths tone signal Hz wavelength ID references and battery charge status 4 Power Port mini USB connection for AC power adapter or PC connection powers unit only no data functionality...

Страница 7: ...key until HELD AOFF appears Wavelength Backlight key Provides two functions Press and hold to toggle the Backlight on or off Press to cycle through the calibrated wavelengths A Note When the OPM4 is r...

Страница 8: ...PM4 switches to the dB measurement mode Note When setting references from multiple wavelength ID d sources allow several seconds prior to setting the references for wavelengths to be ID d and measured...

Страница 9: ...d displays the currently enabled wavelength Single WAVE mode This field displays the detected WAVE ID wavelength Dual WAVE mode This field displays the first detected WAVE ID wavelength Tri WAVE mode...

Страница 10: ...hread on adapter caps 2 Adapter cap the OPM5 optical input must be equipped with an adapter cap 3 Mini USB type B port allows connection to a PC for downloading stored test results interface for AC po...

Страница 11: ...File Manager File mode screen File mode press to increment the File number Fiber and Recall mode press to increment the Fiber number Arrow Fiber key Provides several functions Testing mode press and...

Страница 12: ...ion next Fiber of the current File File Fiber Recall Clear mode press this key to return to the Test mode Recall key Press this key to enter the Recall mode that allows viewing and deleting stored tes...

Страница 13: ...the currently enabled wavelength Single WAVE mode This field displays the detected WAVE ID wavelength Dual WAVE mode This field displays the first detected WAVE ID wavelength Tri WAVE mode This field...

Страница 14: ...w Fiber key to enter the File Manager Fiber mode screen 2 A blinking cursor A to the left of Fiber indicates that you are in the Fiber mode FILE FIBS 22 4 A B C D E 3 Use the arrow keys to increment d...

Страница 15: ...File Management system allows simple organization of power or insertion loss measurements into multiple files Using the supplied Test Results Management TRM software Windows compatible and USB connect...

Страница 16: ...w the following data 0 22 0 22 1310 1310 dB dB nm 4 4 FIBR FIBR WAVE ID A B E C D nm Hz A Fiber number B Wavelength C Stored test result D WAVE ID icon if WAVE ID was active when the measurement was t...

Страница 17: ...ed File to erase 2 Press and hold the Recall Store Clear keys to erase the current file 3 The message Stor to clr FILE appears on the display 4 Press the Store key to delete all fibers for the current...

Страница 18: ...dual Wave 850 and 1300 indicator ON continuous light WAVE ID single Wave corresponding indicator ON continuous light CW corresponding indicator ON blinking light 3 850 1300 CW key Wavelengths select...

Страница 19: ...00 nm 850 nm Press the key to return to the WAVE ID mode at the currently selected wavelength 4 Power key Press and hold the key until all indicators light up to turn the OLS1 Dual on or off The instr...

Страница 20: ...ire replacement 5 Output port Universal Connector Interface UCI Accepts swappable SC connector ST FC and LC connector styles are available 6 Active Output indicators The Active Output indicators light...

Страница 21: ...Adjust mode is valid in CW and single WAVE ID modes only Note If the Output Adjust mode is enabled while the OLS2 Dual is transmitting Dual WAVE ID the unit will switch to the 1310nm WAVE ID mode If...

Страница 22: ...to select the desired operating mode When the OLS2 Dual operates in WAVE ID Mode WAVE ID indicator on Press the Mode key to switch the unit from the WAVE ID to CW mode The WAVE ID indicator will turn...

Страница 23: ...placement 5 MM output port Universal Connector Interface UCI Accepts swappable SC connector ST FC and LC connector styles are available 6 SM output port Universal Connector Interface UCI Accepts swapp...

Страница 24: ...D mode at the currently selected wavelength 9 1310 1550 CW key Single mode wavelengths select key provides several functions as follows WAVE ID Mode Press the key to select wavelengths in the followin...

Страница 25: ...rface UCI Accepts swappable SC connector ST FC and LC connector styles are available 6 Active Output indicators The Active Output indicators light up when the corresponding output port is on 7 Wavelen...

Страница 26: ...he shortest wavelength When the OLS7 3 operates in CW mode CW indicator on Press the Mode key to switch the unit from the CW mode to 2kHZ Tone mode The CW indicator will turn off and the 2kHz Tone ind...

Страница 27: ...lacement 5 Output port Universal Connector Interface UCI Accepts swappable SC connector ST FC and LC connector styles are available 6 Active Output indicators The Active Output indicators light up whe...

Страница 28: ...ue to transmit the shortest wavelength When the OLS7 FTTH operates in CW mode CW indicator on Press the Mode key to switch the unit from the CW mode to 2kHZ Tone mode The CW indicator will turn off an...

Страница 29: ...adapter cap must match the connector on the end of the test jumper you will connect to the OPM 4 Connect one end of the test jumper to the OPM adapter cap and the other end to the optical output to be...

Страница 30: ...ry press the dB dBm key to display optical power in dBm 8 If measured output power is outside of the normal range specified by manufacturer clean all fiber connections or replace the transmit jumper R...

Страница 31: ...llows Observe the displayed power level This is the mated connector pair insertion loss of the test jumpers in dB If the insertion loss is not acceptable disconnect the transmit and receive jumpers at...

Страница 32: ...f using OPM4 Record link insertion loss at the current test wavelength If using OPM5 Press the Store key on the OPM5 to save the displayed measurement in the next available memory location 20 Repeat s...

Страница 33: ...OPM If necessary press the dB dBm key to display optical power in dBm 8 If measured output power is outside of the normal range specified by manufacturer clean all fiber connections or replace the tr...

Страница 34: ...s follows Observe the displayed power level This is the mated connector pair insertion loss of the test jumpers in dB If the insertion loss is not acceptable disconnect the transmit and receive jumper...

Страница 35: ...f using OPM4 Record link insertion loss at the current test wavelength If using OPM5 Press the Store key on the OPM5 to save the displayed measurement in the next available memory location 20 Repeat s...

Страница 36: ...luid Note if using isopropyl alcohol IPA be sure to use 99 pure IPA that has not been contaminated Dampen a portion of the wipe with the cleaning fluid Gently wipe the exposed OPM port starting with t...

Страница 37: ...STD 45662A ISO Guide 25 and traceability to the National Institute of Standards and Technology Call Customer Service to obtain a Service Request S R number before sending units in for calibration Batt...

Страница 38: ...Thank you for choosing NOYES Test and Inspection www AFLglobal com go NOYES CERTIFIED ISO 9001 NOYES www AFLglobal com go NOYES or 1 800 321 5298 1 603 528 7780...

Отзывы: