♦Detecting cables, electrical lines, water/gas supply pipelines buried in wall or earth;
♦Detecting interruptions and short circuit in cables and electrical lines buried in wall 
  

earth;

or 

♦Detecting fuses and assigning current circuits; 
♦Tracing sockets and distribution sockets having accidentally been covered by plastering;
♦Detecting interruptions and short-circuits in floor heating;
♦The transmitter is integrated with the function of AC/DC voltmeter, which can measure 
  12 to 400V AC/DC voltage on a linear basis:
  AC: 12 ~ 400V (50 to 60 Hz) ± 2.5%
  DC: 12

400V ±2.5%

♦The screen of the transmitter can display preset transmitting power, transmitted codes, 
  its own battery energy, mains voltage detected, AC/DC status of mains voltage detected, 
  and warning symbol for mains voltage.
♦The transmitter has the function of self-inspection to detect its own working status 
  

to display it on the LCD screen for user's reference.

and 

♦The screen of the receiver can display the transmitting power of the transmitter, 
  transmitted codes, energy of the transmitter's and its own batteries, AC voltage induced 
  signal detected and warning symbol for mains voltage.
♦The sensitivity of the receiver can be adjusted either manually or automatically.
♦The receiver can sweep frequency automatically.
♦Both the transmitter and the receiver can work under mute mode.
♦The receiver is available with automatic shutdown (It is powered off automatically 
  over 15 minutes of absence of keystroke).
♦The receiver's LCD screen is provided with backlight for application in poor light.
♦Both the transmitter and the receiver is provided with flash light function when 
  working in darkness.
♦Additional transmitters are available to extend or distinguish several signals.
♦Compactness, durability and portability.

1.2 Characteristics of  Cable  Locator NF-826

1.3 Names and Functions of Parts 

1.3.1 Sketch of transmitter

. LCD screen.

. Power on/off key.

. Up key. When setting power level or code, 

      press it to go up.

. Down key. When setting power level or code, 

      press it to go down.

. Key for turning on/off flashlight.

. Key for setting/confirming code information 

      to be transmitted. Press this key for 1 second 
      to enter code setting and press it briefly to 
      exit setting

. Key for setting/confirming transmitting power 

      level (Level I, II or III)

. Key for Mute or Backlight

. Key for transmitting or stopping to transmit 

      code information.

. Grounding hole. The transmitter is grounded 

      with the test lead through this hole.

     

.  “+" hole, input/output hole of the transmitter. 

      The transmitter is connected to external cables 
      with the test lead through this hole to send out 
      signals and receive detected voltage signals.

1.3.2 Transmitter display

Symbol to indicate mains voltage.

Transmitting code.

Mains DC voltage

Mains AC voltage

Mains voltage value (can be used as an 

    ordinary voltmeter; range:12~400v DC/AC)

Code being transmitted.

Intensity of signal being transmitted.

Transmitting power level.

Symbol to indicate mute mode.

Transmitting status.

03

04

Your excellent helper in measuring instruments

.

Your excellent helper in measuring instruments

.

Содержание NF-826

Страница 1: ...Your excellent helper in measuring instruments Your excellent helper in measuring instruments NF 826 VER V1 UNDERGROUND WIRE LOCATOR UNDERGROUND WIRE LOCATOR USER MANUAL USER MANUAL ...

Страница 2: ...nd metal heating pipe 3 1 5 Locating of line interruptions using two transmitters 3 1 6 Error detection for an electrical floor heating 3 1 7 Track an underground circuit 3 1 8 Detect the power supply circuit on the same floor 3 2 Dual pole applications 3 2 1 Search for the fuses 3 2 2 Search for short circuit in the circuit 3 2 3 Applications in closed circuits 3 2 4 Classify or determine the lai...

Страница 3: ...is NF 826 Cable Locator developed by our company to effectively assist users to locate and detect cables you no longer need to take your chance This Cable Locator is a portable instrument consisting of a transmitter a receiver and some accessories With advanced integrated parts and digital circuit technologies it is characterized by highly stable and reliable electrical performance The transmitter...

Страница 4: ... off automatically over 15 minutes of absence of keystroke The receiver s LCD screen is provided with backlight for application in poor light Both the transmitter and the receiver is provided with flash light function when working in darkness Additional transmitters are available to extend or distinguish several signals Compactness durability and portability 1 2 Characteristics of Cable Locator NF...

Страница 5: ...ted to the earth may be live in the event of an error if the earth resistance does not comply with the prescriptions 2 When the transmitter is connected with live mains if the Grounding hole of the transmitter is connected with protective ground phase the current leakage if any in the power supply line may join the circuit current of the transmitter leading to tripping of the leakage circuit break...

Страница 6: ... leads must also be connected to the transmitter and the same ground See Fig 2 2 Switch on the transmitter via key when the LCD screen of the transmitter will display the initial screen and the buzzer will buzz Press key of the transmitter to enter the screen for setting transmitting level and then press up key or down key to select transmitting power level Level I II or III After this level is se...

Страница 7: ... should be ensured 2 The transition resistance of a line interruption must be higher than 100k Ohm 3 When tracing line interruptions in multi core cables note that all remaining leads in the shielded cable or conductor must be grounded in accordance with the regulations This is required to avoid cross coupling of the fed signals by a capacitive effect to the source terminals The tracing depth for ...

Страница 8: ...must not be charged The transmitter is connected to a metal helical tube metal tube or flexible conduit and an auxiliary ground wire as shown in Fig 3 1 3 The measuring method is the same as that used in the example 1 If there is current in the pipeline cut off the power and correctly earth it when the pipeline is not charged 2 The grounding end should be properly grounded and the grounding end of...

Страница 9: ... 1 5 Connect both transmitters as shown in Fig 3 1 5 Proceed as described in the application example If the transmitters are connected in accordance with Fig 3 1 5 the receiver indicates C on the left side ofthe line interruption If the receiver goes beyond the interruption position towards the right it will display F If you are directly above the interruption no line code is displayed due to the ...

Страница 10: ...ting of the proper sensitivity 4 A second transmitter is not indispensable for this application For single transmitter application see Fig 3 1 6a 3 1 7 Track an underground circuit Preconditions The circuit must not be charged Connect the transmitter in a way shown in Fig 3 1 7 The grounding end of the transmitter must be properly grounded Select the automatic mode of the receiver Use the displaye...

Страница 11: ...s on the socket of any residence to feed the signals from the transmitter as shown in Fig 3 2 1 and adjust the transmitting power of the transmitter to a suitable level Preconditions Turn off all the air switches in the distribution box Connect the transmitter according to Fig 3 2 1 When connecting charged circuits to the transmitter please do abide by the safety instructions 1 The identification ...

Страница 12: ...osition is where the short circuit locates 3 Adjust the transmitting power of the transmitter to adapt to different radiuses of detection 4 Select the manual mode on the receiver and select suitable receiving sensitivity to precisely locate the circuit 3 2 3 Applications in closed circuits It can be applied to charged circuits and uncharged circuits In uncharged circuits the transmitter only sends...

Страница 13: ...rt distance between the feeding line and the loop line causes a seriously distorted magnetic field Magnetic field with sufficient strength cannot be built up at the narrow parts If a separate loop line is used this problem would be easily solved as the separate conductor can make the magnetic field diffused more strongly The loop line may be any kind of conducting wires or cable reels The importan...

Страница 14: ...mode on the receiverand select suitable receiving sensitivity to precisely locate the circuit 3 4 Identify voltage in the grid and search for breakages in the circuit Preconditions The circuit must be charged with AC voltage The measurement must be conducted according to Fig 3 4 Set the transmitter to Grid Voltage Identification mode namely the UAC mode 1 The AC signals detected by the transmitter...

Страница 15: ... and standard symbols are used to distinguish AC and DC circuits see in the interface displayed on the transmitter and the upper part of the monitor shows a lightning symbol with a triangular frame see in the interface displayed on the transmitter The range of identification is 12 400V DC AC AC 50 60Hz 4 2 Flashlight function Press the flashlight button on the transmitter or flashlight button on t...

Страница 16: ...ipped with clean water or neutral detergent to wipe the transmitter and then use a dry rag to wipe it again 6 2 Checking of the fuse of the transmitter The fuse of the transmitter can prevent the transmitter from being damaged by overload or wrong operations If the fuse in the transmitter has already been melted down the transmitter can only transmit weak signals If the self check of transmitter i...

Отзывы: