Click = Relay actuated, Clack = Relay dropping
Number of click-clacks
When
Status-Information
1x
the power is on
Normal operation: The system works without any
problem
1x
up button pressed
Reset: initialization procedure required
7x
during movement connec-
tion with a drive is lost
error: Table cannot be moved any more
2x
setting a container
or shelf – stop
confirmation of the limit position successfully saved
(only with the up&down hand switch without
display)
4x
delete container
or shelf – stop
confirmation for the successful deletion of the
limited position (only with the up&down hand switch
without display)
7x
the table moves unevenly
error: the drives do not have the same height, initiali-
sation procedure required
EN
29
Note:
If a power failure occurs or the power cord is pulled out during height adjust-
ment, initialization/start-up may be necessary.
If an error cannot be fixed as described above, unplug the power supply, wait a few minutes, and try the
system initialisation / first start-up procedure again.
If the error persists, disconnect the power supply and contact Customer Service.
11.
Klick-Codes
As soon as the control module is supplied with power, the controller uses integrated relay to acoustically
inform the user about system status and the reason for the most recent shut-down.
Symbol
on the
display
Description
Solution
Display after
troubleshooting
Parameter error
Use the
menu to restore the factory setting.
If this does not correct the error, the control unit must
be replaced or a valid parameter set must be loaded
via CON.STAND.
an
initialization
run is required
The table moves,
height display
cm Display without decimal point,
Inch Display with decimal point and
one decimal place.
—