EN 10
Install the lower spacer bracket on the vertical axis 100 mm from the upper side of the mounting bracket to the
centre of the drilled hole. Use the plugs (906115) and the screws (906197). Mount the spacer bracket such, that it is
perpendicular to and in the centre of the vertical axis on the wall.
Place the supplied exhaust pipe (906-217) onto the connection nozzle using the supplied aluminium tape (906-292)
or using a hose clamp (not included). Extend the exhaust pipe until against the inlet of the carbon filter box and fix it
with aluminium tape or a hose clamp. Then put the plug into the socket outlet.
Remove the stainless steel shaft set from the packaging of the hood. Slide the upper shaft out of the lower shaft and
turn it around, so the grate is at the top. Slide the upper shaft back into the lower shaft.
Move the shafts beyond the recirculation box unto the ceiling and then push them behind the recirculation box!
Lower the outer shaft unto the chimney hood. Clamp the outer shaft onto the lower spacer. Open the bottom plate
and remove the filter from the chimney hood. Tighten the shaft from the inside of the chimney hood with the 4 screws
(906151).
Push the upper shaft behind the carbon filter box. Then tighten them using the corresponding stainless steel screws
(2 x 906-035).
Install the Monoblock recirculation filter
Open the bottom plate and remove the aluminium fat filter from the chimney hood.
Place the Monoblock recirculation filter (7600055) in the opening provided.
Place the fat filter in the chimney hood again and close the bottom plate.
Programme the Monoblock recirculation filter
Attention! Do the programming with the motor switched off.
Programme:
Simultaneously press the + and the – keys for 5 seconds until the red LED flashes 5 times. The following functions have
now been enabled:
• The run-out time has been set to 30 minutes (instead of the default 10 minutes).
• The cleaning indicator for the Monoblock recirculation filter has been set to 200 operating hours.
The red LED will light up after 200 operating hours. This indicates that the Monoblock recirculation filter needs cleaning
(see the instructions below).
Re-programming:
Simultaneously press the + and the – keys for 5 seconds. The red LED will flash 5 times for confirmation. If the program-
ming is not carried out, the programming is automatically set after the chimney hood has been switched on 10 times.
Inactivate the programming (the motor must have been switched on):
Simultaneously press the + and the – keys for 5 seconds until the 3rd green LED flashes 5 times.
Clean the Monoblock recirculation filter
The Monoblock recirculation filter can be regenerated up to 12 times. This is done in the oven:
• Place the filter in the oven for 1 hour at 120°C. Provide sufficient fresh air in the room where the oven has been
placed, as smells can be released.
• Smells can be released when baking certain kinds of fish. In this case it is best to immediately regenerate the filter in
the oven.
Changes and misprints reserved, March 2013