background image

NVS

-

5116SP / NVS

-

5124SP 

-

 User

s manual ver. 1.0

 

All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.

 

 

3

 

WARNING!

 

THE KNOWLEDGE OF THIS MANUAL IS AN INDESPENSIBLE CONDITION OF A 
PROPER DEVICE OPERATION. YOU ARE KINDLY REQUSTED TO FAMILIRIZE 
YOURSELF WITH THE MANUAL PRIOR TO INSTALLATION AND FURTHER 
DEVICE OPERATION.

 

WARNING!

 

USER  IS  NOT  ALLOWED  TO  DISASSEMBLE  THE  CASING  AS  THERE  ARE  NO      
USER

-

SERVICEABLE  PARTS  INSIDE  THIS  UNIT.  ONLY  AUTHORIZED  SERVICE 

PERSONNEL MAY OPEN THE UNIT 

 

INSTALLATION  AND  SERVICING  SHOULD  ONLY  BE  DONE  BY  QUALIFIED  SERVICE 
PERSONNEL AND SHOULD CONFORM TO ALL LOCAL REGULATIONS

 

 

WARNING!

 

PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN 
PRODUCT IN USER

S MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE 

PRODUCT, OR IF IT DOES NOT ARISE FROM THE USUAL APPLICATION OF THE 
PRODUCT,  MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR OF 
EXCLUDING THE MANUFACTURER

S  RESPONSIBILITY FOR THE RESULTS OF SUCH AN 

ACTION.

 

IMPORTANT SAFEGUARDS AND WARNINGS

 

1.

 

Prior  to  undertaking  any  action  please  consult  the  following  manual  and  read  all  the  safety  and 
operating instructions before starting the device.

 

2.

 

Please keep this manual for the lifespan of the device in case referring to the contents of this manual 
is necessary;

 

3.

 

All  the  safety  precautions  referred  to  in  this  manual  should  be  strictly  followed,  as  they  have  a 
direct influence on user

s safety and durability and reliability of the device;

 

4.

 

All  actions conducted by  the servicemen and users must be accomplished in  accordance with  the 
user

s manual;

 

5.

 

The device should be disconnected from power sources during maintenance procedures;

 

6.

 

Usage  of  additional  devices  and  components  neither  provided  nor  recommended  by  the  producer    
is forbidden;

 

7.

 

Mounting  the  device  in  places  where  proper  ventilation  cannot  be  provided  (e.  g.  closed  lockers 
etc.)  is  not  recommended  since  it  may  lead  to  heat  build

-

up  and  damaging  the  device  itself               

as a consequence;

 

8.

 

Mounting  the  device  on  unstable  surface  or  using  not  recommended  mounts  is  forbidden. 
Improperly mounted switch may cause a fatal accident or may be seriously damaged itself. Switch  
must be mounted by qualified personnel with proper authorization, in accordance with this user

manual;

 

IMPORTANT SAFEGUARDS AND WARNINGS

 

Содержание NVS-5116SP

Страница 1: ...User s manual NVS 5116SP NVS 5124SP...

Страница 2: ...T MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR OF EXCLUDING THE MANUFACTURER S RESPONSIBILITY FOR THE RESULTS OF SUCH AN ACTION DIRECTIVE 2014 35 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of...

Страница 3: ...t the following manual and read all the safety and operating instructions before starting the device 2 Please keep this manual for the lifespan of the device in case referring to the contents of this...

Страница 4: ...ersonnel 13 Unplug the switch from the power source immediately and contact the proper maintenance department when the following occurs Damages to the power cord or to the plug itself Liquids getting...

Страница 5: ...ports can be connected conveniently to NVR and other high bandwidth device UPLINK optical port SFP is designed for SFP optical fiber modules solving problem of long distance transmission Fast and easy...

Страница 6: ...capacity power supply UPLINK SFP Port 1Gb s 2 Uplink Combo x 2 SFP 1Gb s RJ45 1Gb s PoE standards IEEE802 3 af IEEE802 3 at PoE modes Endspan 1 2 3 6 Switching capacity 11 2 Gb s Protocols Support IEE...

Страница 7: ...power supply Ports RJ 45 UPLINK 1Gb s 2 Uplink Combo x 2 SFP 1Gb s RJ45 1Gb s PoE standards IEEE802 3 af IEEE802 3 at PoE modes Endspan 1 2 3 6 Switching capacity 12 8 Gb s Protocols Support IEEE 802...

Страница 8: ...nage switch via web browser Device IP address is 192 168 0 1 login and password is root pass It is required to set computer IP address in the same IP address group address as switch due to lack of DHC...

Страница 9: ...is a tab where user can set connection speed and disable or enable the port In Bandwidth Control tab user can limit the bandwidth for individual ports or for the group of ports 3 3 PoE Configuration t...

Страница 10: ...TCH MANAGEMENT 3 4 VLAN is helpful in cases where there are too many devices working in network VLAN functions allow to separate workstation computers from cameras or servers In this tab we can set ty...

Страница 11: ...T 3 6 Administrator tab allows to change switch IP address settings user accounts etc 3 6 1 Account Password this tab allows to change admin username and password 3 6 2 Configuration this tab allows t...

Страница 12: ...User s manual ver 1 0 All rights reserved AAT SYSTEMY BEZPIECZE STWA sp z o o 12 AAT SYSTEMY BEZPIECZE STWA Sp z o o 431 Pulawska St 02 801 Warsaw Poland tel 4822 546 0 546 kontakt aat pl www novuscct...

Страница 13: ...NVS 5116SP NVS 5124SP Instrukcja obs ugi...

Страница 14: ...yk ego przeznaczenia Produktu nale y pod rygorem wy czenia odpowiedzialno ci Producenta za nast pstwa takiej czynno ci skontaktowa si z Producentem DYREKTYWA PARLAMENTU EUROPEJSKIEGO I RADY2014 35 UE...

Страница 15: ...ykonywane przez instalator w i u ytkownik w musz by realizowane zgodnie z opisem zawartym w instrukcji 5 W czasie czynno ci konserwatorskich urz dzenie musi by od czone od zasilania 6 Nie wolno stosow...

Страница 16: ...uj cych przypadkach Uszkodzenia przewodu zasilaj cego lub wtyczki tego przewodu Przedostania si cieczy do rodka urz dzenia lub gdy zosta o ono nara one na silny uraz mechaniczny Urz dzenie dzia a w sp...

Страница 17: ...et mo na pod czy NVR albo inne urz dzenia wymagaj ce wy szego transferu UPLINK optyczny zarezerwowany jest dla modu w wiat owodowych SFP dzi ki kt rym zapewniona jest transmisja na du odleg o Szybki i...

Страница 18: ...trybie PoE ograniczona Porty RJ 45 UPLINK 1Gb s 2 Uplink Combo x 2 SFP 1Gb s RJ45 1Gb s Standardy PoE IEEE802 3 af IEEE802 3 at Tryb zasilania PoE Endspan 1 2 3 6 czna przepustowo 11 2 Gb s Obs ugiwa...

Страница 19: ...ograniczona wydajno ci zasilacza Porty SFP UPLINK 1Gb s 2 Uplink Combo x 2 SFP 1Gb s RJ45 1Gb s Standardy PoE IEEE802 3 af IEEE802 3 at Tryb zasilania PoE Endspan 1 2 3 6 czna przepustowo 12 8 Gb s Ob...

Страница 20: ...i internetowej Po uruchomieniu adresu http 192 168 0 1 i wpisaniu u ytkownika root i has a pass uka si funkcje prze cznika Aby zalogowa si do menu prze cznika nale y ustawi adres IP z tej samej grupy...

Страница 21: ...iguration to zak adka w kt rej mo emy ustawi pr dko po czenia i wy czy lub w czy port W zak adce Bandwidth Control znajduje si mo liwo zmiany maksymalnej przepustowo ci dla port w 3 3 Zak adka PoE Set...

Страница 22: ...NIKIEM 3 4 VLAN MANAGMENT jest pomocny w razie gdy jest zbyt du o urz dze w obr bie jednego prze cznika Po ustawieniu VLANa mo emy oddzieli komputery od kamer czy serwer w W poni szej zak adce wybiera...

Страница 23: ...a Administrator pozwala na zmian loginu i has a dla u ytkownika o uprawnieniach administratora 3 6 1 Zak adka Account Password pozwala na zmian loginu i has a administratora 3 6 2 Zak adka Configurati...

Страница 24: ...ukcja obs ugi wer 1 0 Wszelkie prawa zastrze one AAT SYSTEMY BEZPIECZE STWA sp z o o 12 AAT SYSTEMY BEZPIECZE STWA Sp z o o ul Pu awska 431 02 801 Warszawa Polska tel 22 546 0 546 kontakt aat pl www n...

Отзывы: