WWW INTERFACE
-
WORKING WITH IP CAMERA
In first step write number of licence plate and select the type of the list. In the next step select the date
for
Begin
and
End Time
(it define activity time of the licence plate in the camera data base).
WARNING!
The
End Time
by default is set one day after currently set time in the camera. Not changing the
End Time
may result in problems related to the automatic removal of tables from the list.
After configuration press to save the changes.
Press the
Advance
button to configure the reactions for list types.
WARNING!
For
White list
there is turned on
Relay ON
reaction by default.
6.3.2.
Parameter Configure
Using slider set the
Minimum Width of Licence Plate (pixel)
on the image, than write the vehicle's
approach angle, based on the diagram located on the right side of the camera image and draw a zone
where the plates can be detect. The more accurate zone, greater the probability of correctly detecting
of the plate number.
6.3.3.
Linkage Configure
In this menu configure the reactions for licence plate detection. Define the operating mode of Relay
Output (NO or NC) in
Valid Signal
position and the
Time Of Duration(sec.)
the alarm after licence
plate detection. In the next positions turn on/off the
FTP Upload ScreenShots
and
Video Displaying
License Plate
of detected plates. This option is using to show the number of License Plate on OSD,
write the
Time of Duration
for displaying this OSD.