5.4 Connecting alarm inputs/outputs.
Alarm input/output connectors are described in the chapter 2.1 of this user’s manual.
Alarm input
Alarm input connections
Alarm output
Alarm output relay maximum load:
30VDC / 500mA.
Alarm output connections
6. RESTORING FACTORY DEFAULTS
NOVUS IP camera NVIP-2C5000ATM allow to restore defaults via software (web browser level)
resetting the camera settings
6.1. Restoring software factory defaults
Restoring factory software default can restore default settings of the IP camera, optionally network
settings can be saved.
Logon to the camera and choose
MAINTENANCE
. Check the
Save the IP setting
box to preserve IP
setting after restore. Click
Restore
button. The camera re-starts then, taking about two minutes to
complete. Log on using default user name (root) and password (pass)
ELECTRIC CONNECTORS AND ACCESORIES