Novus NT240 Скачать руководство пользователя страница 4

Timer NT240 

NOVUS AUTOMATION 

4/5

 

TIMER OPERATING MODES 

The timer offers 11 predefined operating modes plus the possibility 

for the user to customize his own mode of operation, by configuring 

parameters 

t1.S1

 to 

t1.S5

. Modes 0 to 10 are the predefined ones, 

whereas mode 11 left to the user control. They are described below: 

Mode 0 – Delayed activation after power-up 

 

Out 1

 

Power

 

t1.SP

 

Reset

 

t1.SP

 



 



 

 

T1.S1 

 to  

T1.S5

 are automatically set to: 

T1.S1 

T1.S2 

T1.S3 

T1.S4 

T1.S5 

 

The  

F

 key can be programmed either as Reset or Reset/Hold. 

Mode 1 – Delayed pulse after power-up 

 

Out 1

 

Power

 

t1.SP

 

ou1.t

 

Reset

 

t1.SP

 

t1.SP

 



 

                                                

 



 

               

 



 

                             

 



 

                                                 

 



 

                                     

 



 

 

T1.S1 

 to  

T1.S5

 are automatically set to: 

T1.S1 

T1.S2 

T1.S3 

T1.S4 

T1.S5 

 

The  

F

 key can be programmed either as Reset or Reset/Hold. 

Mode 2 – Pulse at power-up 

 

Out 1

 

Power

 

t1.SP

 

Reset

 

t1.SP

 



 

              

 



 

              

 



 

        

 



 

 

T1.S1 

 to  

T1.S5

 are automatically set to: 

T1.S1 

T1.S2 

T1.S3 

T1.S4 

T1.S5 

 

The 

F

 key can be programmed either as Reset or Reset/Hold. 

Mode 3 – Cyclic after power-up 

 

Out 1

 

Power

 

t1.SP

 

ou1.t

 

t1.SP

 

Reset

 

t1.SP

 

ou1.t

 



 

                              

 



 

                              

 



 

        

 



 

                             

 



 

                               

 



 

                                            

 



 

 

T1.S1 

 to  

T1.S5

 are automatically set to: 

T1.S1 

T1.S2 

T1.S3 

T1.S4 

T1.S5 

 

The  

F

 key can be programmed either as Reset or Hold. 

Mode 4 – Pulse after momentary Start signal 

 

Start

 

t1.SP

 

Out 1

 

t1.SP

 

t1.SP

 

  

 



 

     

 



 

     

 



 

              

 



 

         

 



 

      

 



 

Reset

 

t1.SP

 

 

T1.S1 

to  

T1.S5

 are automatically set to: 

T1.S1 

T1.S2 

T1.S3 

T1.S4 

T1.S5 

 

The  

F

 key can be programmed as Reset/Hold. 

Mode 5 – Extended pulse after output is turned off 

 

Start

 

t1.SP

 

Out 1

 

          

 



 

               

 



 

                               

 



 

                                             

 



 

Reset

 

t1.SP

 

t1.SP

 

 

T1.S1 

to  

T1.S5

 are automatically set to: 

T1.S1 

T1.S2 

T1.S3 

T1.S4 

T1.S5 

 

The  

F

 key can be programmed as Reset/Hold. 

Mode 6 – Delayed output after momentary START signal 

 

Start

 

t1.SP

 

Out 1

 

t1.SP

 

  

 



 

                                             

 



 

                        

 



 

Reset

 

 

T1.S1 

 to  

T1.S5

 are automatically set to: 

T1.S1 

T1.S2 

T1.S3 

T1.S4 

T1.S5 

 

The  

F

 key can be programmed as Reset/Hold. 

Mode 7 – Delayed pulse after momentary START signal 

 

Start

 

t1.SP

 

Out 1

 

t1.SP

 

   

 



 

                                  

 



 

                                            

 



 

                                 

 



 

                                  

 



 

                                             

 



 

Reset

 

ou1.t

 

ou1.t

 

t1.SP

 

 

T1.S1 

to  

T1.S5

 are automatically set to: 

T1.S1 

T1.S2 

T1.S3 

T1.S4 

T1.S5 

 

The  

F

 key can be programmed as Reset/Hold. 