![background image](http://html1.mh-extra.com/html/novus/nr7020-ro/nr7020-ro_manual_1712919076.webp)
Users manual
$GPNVS
Revision #:
T
Date:
2/15/22
Page #:
14 of 28
www.novuspower.com
1.9.2 Status String ($GPNVS,9) Frequency Measurement (HS)
$GPNVS 9 nnnnnnn.nnn n.nnnnn nnnnnnnn.nn 0 ±n.nn ±n.nn ±n.nn ±n.nn *
XX
1
2
3
4
5
6
7
8
9
10
11
# Description
Range
1.
Identifier
$GPNVS
2.
String ID
9
3.
Frequency (Loop Period)
10000000.000
4.
DAC Voltage (Double)
2.00000
5.
Frequency (per second)
10000000.0
6.
Loop Period
0-99
7.
Antenna Current Mon
0.00 to 3.30V
8.
Sine Output RMS
0.00 to 3.30V
9.
Battery Voltage
0.00 to 24.0V (or NULL)
10.
Temperature
-40.0 to 99.9C
11.
NMEA Checksum
*XX (xor’d value of bytes between $ and *)
Example:
$GPNVS,9,+10000000.003,+1.97493,+10000000.0,15,+1.03,+1.30,,28.2*4A