Users manual
NR2316-OG
Revision #:
E
Date:
5/4/18
Page #:
45 of 50
www.novuspower.com
Primary and
Secondary
Power Supply
Status
Hex Value (OR'd)
Status Message
0x1<<0
Source Input A out of range
0x1<<1
Source input B out of range
0x1<<2
Digital PS out of range
0x1<<3
Analog (+) PS out of range
0x1<<4
Analog (-) PS out of range
0x1<<5
Communication Failure
0x1<<6
DC Power not present (option)
0x1<<7
AC Power not present
Active Board
Hex Value (OR'd)
Status Message
0x1<<14
Channel 15 Fault
Backup PCB Amp Status
Hex Value (OR'd)
Channel ID
Backup PCB Amp Status
0x1<<0
Channel 1 Fault
Internal Fault Backup
Assembly: The channel
has failed an internal
gain test on the backup
PCB assembly, and the
channel is not functional
on the secondary board.
Amp Gain Test for Alert is
enabled with $AMP=1
command via RS232
0x1<<1
Channel 2 Fault
0x1<<2
Channel 3 Fault
0x1<<3
Channel 4 Fault
0x1<<4
Channel 5 Fault
0x1<<5
Channel 6 Fault
0x1<<6
Channel 7 Fault
0x1<<7
Channel 8 Fault
0x1<<8
Channel 9 Fault
0x1<<9
Channel 10 Fault
0x1<<10
Channel 11 Fault
0x1<<11
Channel 12 Fault
0x1<<12
Channel 13 Fault
0x1<<13
Channel 14 Fault
0x1<<14
Channel 15 Fault
Содержание NR2316-OG
Страница 6: ...Users manual NR2316 OG Revision E Date 5 4 18 Page 6 of 50 www novuspower com ...
Страница 28: ...Users manual NR2316 OG Revision E Date 5 4 18 Page 28 of 50 www novuspower com 4 0 Functional Description ...
Страница 35: ...Users manual NR2316 OG Revision E Date 5 4 18 Page 35 of 50 www novuspower com Kalman Filter Performance ...
Страница 92: ...Users manual Appendix A Revision A Date 07 14 15 Page 42 of 58 Pps status present pps is sync with UTC USNO ...