Users manual
NR2110-OG
Revision #:
J
Date:
3/17/17
Page #:
37 of 46
www.novuspower.com
Setting
Command
Response
Description
SET INDIVIDUAL
CHANNEL
REFERENCE
VOLTAGE
$SET<nn>=n.nn
$SET<nn>=nn.nn
Set or query the Reference Voltage for a perticular
channel with respect to the active input. Use in
combination with the Channel Fault Threshold
Factor to define Alert on an individual Channel.
Reference Voltages are set with respect to the
active input, allowing for variation in amplitude
between Input A and Input B.
Example: Set Channel 4 to Alert if it is beyond
+/-20% of 0.90Vrms when relayed to Input A:
$SET04=0.90<CR><LF>
$FLTTHR=0.20<CR><LF>
( To set all channel Reference values to their current
average amplitude, use the Latch Average Channel
Values command.)
$SET01=1.00
$SET02=1.00
$SET03=1.00
.
.
.
$SET15=1.00
LATCH AVERAGE
CHANNEL
VALUES
$LATCHAVG
$LATCHAVG=<currently Selected
input>
Latches the current Channel Vrms measurement
averages into memory as the average value to set
the Channel Fault Threshold for each channel.
Latches in all outputs with respect to the active
input.
Example: Response of "LATCHAVG=A" indicates
input A is active, and the channel fault thresholds
for Input A will now measure against the current
output values. Use this command during setup,
after cabling, to take a snapshot of the nominal
system state.
NVS1 OUTPUT
$NVS1
$NVS1=< current NVS1 STRING
output frequency >
Query NVS1 String output Frequency. (Default = 1)
$NVS1=1
Change NVS1 String output Frequency in seconds.
(0-60)
NVS2 OUTPUT
$NVS2
$NVS2=< current NVS2 STRING
output frequency >
Query NVS2 String output Frequency. (Default = 1)
$NVS2=1
Change NVS2 String output Frequency in seconds.
(0-60)
NVS3 OUTPUT
$NVS3
$NVS3=< current NVS3 STRING
output frequency >
Query NVS3 String output Frequency. (Default = 1)
$NVS3=1
Change NVS3 String output Frequency in seconds.
(0-60)
NVS4 OUTPUT
$NVS4
$NVS4=< current NVS4 STRING
output frequency >
Query NVS4 String output Frequency. (Default = 1)
$NVS4=1
Change NVS4 String output Frequency in seconds.
(0-60)
Содержание NR2110-OG
Страница 3: ...Users manual NR2110 OG Revision J Date 3 17 17 Page 3 of 46 www novuspower com...
Страница 24: ...Users manual NR2110 OG Revision J Date 3 17 17 Page 24 of 46 www novuspower com 4 0 Functional Description...
Страница 32: ...Users manual NR2110 OG Revision J Date 3 17 17 Page 32 of 46 www novuspower com Kalman Filter Performance...
Страница 88: ...Users manual Appendix A Revision A Date 07 14 15 Page 42 of 58 Pps status present pps is sync with UTC USNO...