Страница 1: ...Manual 1 P a g e Novum Overseas The Novum Building Clonshaugh Ind Est Dublin 17 Ireland info novum ie 353 1 803 6400 Models 410L 401L 610L 601L _______________________________________________________...

Страница 2: ...25 Inner Temperature Range O C 18 to 25 18 to 25 18 to 25 Sound pressure at 1M distance Db A 42 3 42 3 42 3 Nominal Voltage Frequency V Hz 220 240 50 220 240 50 220 240 50 Nominal Power cabinet W 290...

Страница 3: ...nical Manual 3 P a g e Novum Overseas The Novum Building Clonshaugh Ind Est Dublin 17 Ireland info novum ie 353 1 803 6400 Dimensions___________________________________________________________________...

Страница 4: ...___________________________________________________________ Item Part Number Description 1 030 610 027 Compressor Tray 2 030 610 026 Condenser Plate 4 003 801 006 13 5 Gm Filter Dryer 7 003 601 007 Da...

Страница 5: ..._______ Item No Description Part Number 1 Kick Strip 006 111 285 2 Castor Rail 030 610 106 3 Caster 006 805 226 4 Side Grill 006 111 411 5 Compressor Tray Assembly 6 Condenser Cover 003 610 363 7 Sepa...

Страница 6: ...______ Item No Description Part Number 1 Kick Strip 006 611 085 2 Caster Rail 030 610 106 3 Caster 006 805 226 4 Side Grille 006 111 411 5 6 Compressor Tray Assembly 7 Back Shroud 003 610 363 8 Liner...

Страница 7: ...ical Manual 7 P a g e Novum Overseas The Novum Building Clonshaugh Ind Est Dublin 17 Ireland info novum ie 353 1 803 6400 Refrigeration Circuit_________________________________________________________...

Страница 8: ...verseas The Novum Building Clonshaugh Ind Est Dublin 17 Ireland info novum ie 353 1 803 6400 Wiring Diagram______________________________________________________________ LED Wiring____________________...

Страница 9: ...efrosting Remove frozen food to a suitably refrigerated area Unplug Cabinet and open lid When frost has melted and cleaning has been complete use a clean dry cloth to mop up excess condensate from the...

Страница 10: ...Service Agent HA Alarm Critical High Cabinet Temperature 1 Check product temp if above 120 C move product 2 Call Service Agent P1 Alarm Not Critical Loose Temperature Probe 1 Call Service Agent P2 Al...

Страница 11: ...obe 10 10 Pr2 0 99 min CH Type of regulation action cL cL Pr2 CF Temperature measurement unit Celsius Fahrenheit C C Pr2 rE Resolution for C decimal integer dE dE Pr2 dy Temperature display delay 2 2...