Ecology Technical Manual
11 |
P a g e
Novum Overseas. The Novum Building. Clonshaugh Ind Est. Dublin 17. Ireland | [email protected] | +353 1 803 6400
Controller Settings ______________________________________________________________
Para Description
Edit
Orig
Vis.
Level
Minimu
m
Maximu
m
Uni
t
SEt
Set point
-
19.0
-
19.0
-25.0
-15.0
°C
Hy
Compressor regulation hysteresis
3.0
3.0
Pr1
0.1
25.5
°C
LS
Minimum Set Point
-
25.0
-
25.0
Pr2
-55.0
-19.0
°C
US
Maximum Set Point
-
15.0
-
15.0
Pr2
-19.0
99.0
°C
ot
Probe calibration P1
0.0
0.0
Pr1
-9.9
9.9
°C
od
Output activation delay at power on
0
0
Pr2
0
99
min
AC
Anti-pendulum delay
3
3
Pr2
0
50
min
Cy
Compressor ON time with faulty probe
30
30
Pr2
0
99
min
Cn
Compressor OFF time with faulty probe
10
10
Pr2
0
99
min
CH
Type of regulation action
cL
cL
Pr2
CF
Temperature measurement unit: Celsius,
Fahrenheit
C
C
Pr2
rE
Resolution (for ° C): decimal, integer
dE
dE
Pr2
dy
Temperature display delay
2
2
Pr1
0
15
min
id
Interval between defrost cycles
0
0
Pr2
0
99
h
Md
Maximum defrost duration
0
0
Pr2
0
99
min
dF
Display during defrost
it
it
Pr2
AU
High temperature alarm
-
10.0
-
10.0
Pr1
-30.0
99.0
°C
AL
Low temperature alarm
-
30.0
-
30.0
Pr1
-55.0
-10.0
°C
Ad
Temperature alarm delay (in normal operation)
15
15
Pr2
0
99
min
dA
Exclusion of temperature alarm at power-on
99
99
Pr2
0
99
min
iP
Polarity digital input
CL
CL
Pr2
iF
Digital input function
EA
EA
Pr2
di
Alarm delay from configurable digital input
5
5
Pr2
0
99
min
dC
Control for open door: fans and compressor
no
no
Pr2
rd
Restart regulation with open door alarm
y
y
Pr2
Pt
EEPROM map identification
2
2
Pr2
0
65535
rL
Firmware release code (read only)
0
0
Pr2