4
MENU BUTTON “
”:
The function of this key is to enter the level one programming mode where the valve
settings can be adjusted.
SET / REGEN BUTTON “
”:
This button has two functions. The first is to initiate a manual regeneration by holding
the button for 3 or more seconds. The second function is while in programming mode,
pressing this key allows the user to change the value of each setting.
UP / DOWN “
”:
These buttons are used to increase or decrease the value of the settings while in the
programming mode.
System Initialization
When power is first supplied, the valve may take up to two minutes to initialize the valve. During this time the valve will
show “INTIALIZING WAIT PLEASE”. Do not touch any buttons at this time. When the valve reaches the service position, it
will display the current date and time.
Figure 4. System Initialization Display
Main Valve Functions
Regeneration Mode:
1. METER DELAYED (FACTORY SETTING)
2. METER IMMEDIATE
3. CALENDAR CLOCK
4. METER OVERRIDE
Capacity Calculation:
1. AUTOMATIC (FACTORY SETTING)
2. MANUAL
Adjustable Cycles:
All of the valve cycles are fully adjustable.
1. BACKWASH
2. BRINE / RINSE
3. RINSE
4. REFILL
NOTE:
Refer to Level Two User Programming for description of each mode.
During a regeneration cycle, the valve will display what position it is advancing to. Once in the correct position, the valve
will display the current position along with the time remaining for that cycle. On the bottom row, the time remaining is also
graphically displayed.
BACKWASH
REMAINING 6 MIN
Figure 5. Regeneration Cycle Valve Display
Manual Regeneration (Delayed or Immediate)
If screen is locked, press “
MENU
”
for 3 seconds to unlock. To initiate an immediate regeneration, press the SET / REGEN
button for 3 seconds, an option for delayed or immediate regeneration will appear. Press the SET / REGEN button again and
delayed will begin flashing, press the down arrow button to have immediate flash, press the SET / REGEN button and then
press the menu button and the valve will immediately start into manual regeneration.
To initiate a delayed regeneration, press the SET / REGEN button for 3 seconds, then press the menu button and a
regeneration will be queued to the next pre-set regeneration time (2:00 a.m.).