background image

CONTROL PANEL DESCRIPTION

TECHNICAL SPECIFICATIONS

03

• If using novita Demineralization Filter, DO NOT use in conjunction with novita Air Purifying Solution 

   Concentrate and Naturale Essential Oil Blend and vice versa.

• novita Humidifier can be used with novita’s specially formulated Air Purifying Solution Concentrate and Naturale 

   Essential Oil Blend only. Warranty will not cover any damages caused by the use of other brands/types of pure 

   essential oils/blends/concentrate or other solutions/additives.

Rate Voltage
Humidification Technology
Power Consumption
Humidification Rate
Continuous Humidification
Coverage
Tank Capacity
Empty Weight
Product Dimensions (W x D x H)
Noise Level
Regulated Mist Volume
Optional Product Accessory

220 - 240 V / 50 Hz
Ultrasonic
46 Watts
230 ml/hr
Min. 21 Hours
Up To 180 ft

2

5.0 Litres
3.2 Kg
230 mm x 165 mm x 316 mm

<

29 dB

3 Levels
• Demineralization Filter
• novita Air Purifying Solution Concentrate*
• novita Naturale Essential Oil Blend*

Heat Vaporizing
149 Watt
370 ml
Min. 13 Hours

Mist Volume

Control

Warm

Mode

Power Control

Display Screen

Luminosity Control

Humidity

Setting

Содержание Humiperfect NH890

Страница 1: ...HUMIDIFIER NH890 BREATHE WELL REPLENISH MOISTURE REFRESH AIR QUALITY WITH NOVITA HUMIDIFIER NH890 Please read instructions before using the Humidifier OPERATING INSTRUCTIONS AND E WARRANTY APPLICATION ...

Страница 2: ...BLESHOOTING SAFETY PRECAUTIONS SAFETY INSTRUCTIONS NOVITA CUSTOMER SERVICE GUARANTEE E WARRANTY APPLICATION LIMITED WARRANTY TERMS CONDITIONS LIMITED WARRANTY EXTENSION 02 03 03 04 05 07 10 12 13 14 14 15 15 17 CONTENTS This product includes novita Humidifier NH890 Base 1 xWaterTank 1 x Mist Outlet 1 x Nebulizer Brush Humidifier NH890 Operating Instructions E Warranty Application e copy Starter Gu...

Страница 3: ...dle 03 Water Tank 04 Control Panel 05 Display Screen 06 Demineralization Filter Optional 07 Water Tank Cap 08 Main Body 09 Fan Outlet 10 Water Reservoir 11 Nebulizer 12 Water Level Sensor 13 Nebulizer Brush 14 Power Cord Plug 01 02 03 04 05 06 07 08 14 09 10 11 12 13 TOP VIEW ...

Страница 4: ...s blends concentrate or other solutions additives Rate Voltage Humidification Technology Power Consumption Humidification Rate Continuous Humidification Coverage Tank Capacity Empty Weight Product Dimensions W x D x H Noise Level Regulated Mist Volume Optional Product Accessory 220 240 V 50 Hz Ultrasonic 46 Watts 230 ml hr Min 21 Hours Up To 180 ft2 5 0 Litres 3 2 Kg 230 mm x 165 mm x 316 mm 29 dB...

Страница 5: ...lace However air conditioning systems dry the surrounding air and cause an extreme drop of humidity levels A comfortable atmosphere indoors between 60 to 70 relative humidity is the recommended level Why use UltrasonicTechnology for Humidification UltrasonicTechnology is an extremely effective and economical method of maintaining and moderating the relative humidity level in the surrounding air Ul...

Страница 6: ...ode has definitely got you covered 03 HUMIDITY LEVEL CONTROL Control the level of RH best suited for you and your family with the humidity range from 40 RH to 75 RH at an increment of 5 or continuous mode CO 04 HYGROSTAT PRE SET HUMIDITY LEVEL Equipped with an in built hygrostat that works as an automatic sensor of the surrounding relative humidity and hence facilitates it to continuously moderate...

Страница 7: ...urifying Solution Concentrate that is formulated with NSF certified and EPA registered active ingredient from USA it diligently oxidizes 99 99 of bacteria and virus to protect you and your loved ones Relax into a soothing and alluring ambience scents while breathe well with secured indoor air quality all at once starting today 10 DEMINERALIZATION FILTER The demineralization filter is designed to r...

Страница 8: ...OT use water above 40o C When a filled water tank is placed onto the humidifier base the sound of gurgling water is normal as water is travelling from water tank into the water reservoir Remove the unit from all packagings Check and ensure that there are no foreign objects inside the water tank or water reservoir Remove the water tank from the base and fill it with clean tepid or cool water from t...

Страница 9: ... be produced and dispersed into the surrounding air to facilitate faster humidification rate HUMIDITY SETTING Tap button consecutively to select user s preferred humidity level from 40 RH to 75 RH at an increment of 5 or continuous mode The selected RH will flash twice and unit will operate in accordance to the selected setting and shortly the display screen will revert back to the surrounding RH ...

Страница 10: ... apply directly on skin Using Air Purifying Solution Concentrate Essential Oil Blend novita Humidifier can be used with novita s specially formulated Air Purifying Solution Concentrate and Naturale Essential Oil Blend only Warranty will not cover any damages caused by the use of other brands types of pure essential oils blends concentrate or other solutions additives DO NOT sprinkle the novita air...

Страница 11: ...amp cloth to wipe the surface to prevent the accumulation of dust Attach the demineralization filter onto the inner side of the water tank cap Screw and tighten the cap back onto the water tank and place the water tank back onto the unit base 02 If using novita Demineralization Filter DO NOT use in conjunction with novita Air Purifying Solution Concentrate or Naturale Essential Oil Blend and vice ...

Страница 12: ...the Nebulizer Brush provided or a soft cloth IMPORTANT 1 When the Nebulizer is not regularly cleaned the efficiency of the unit will be compromised or even damaged depending on the severity 2 DO NOT clean the Nebulizer with any solvents or aggressive agents 3 DO NOT scratch or rub the surface of the Nebulizer with a sharp article Nebulizer Water Level Sensor Float To Clean theWater Reservoir Pour ...

Страница 13: ...atthe Nebulizer There is a water shortage Water shortage Indicator lit up Ill maintained humidifier Regular maintenance of humidifier Water is unclean Stale water Water Level Sensor float stuck not properly installed Remove the water tank and reattach it onto the water reservoir and ensure it is properly installed Water Leakage The water tank and water reservoir are not connected properly Check to...

Страница 14: ...ed service engineers Improper repair can cause considerable danger to the user DO NOT scratch or rub the surface of the Nebulizer with a sharp article but use the brush provided instead DO NOT pour water directly into the Mist Outlet Fill water only through the Water Tank DO NOT handle the humidifier or power cord with wet hands DO NOT move or incline the humidifier during operation Always unplug ...

Страница 15: ...u Free Evaluation Check in your product for a FREE assessment and evaluation by our qualified technician Upon your confirmation charges only apply when there is replacement of technical parts Minimum Downtime Understanding that time is of the essence for each servicing or repair novita guarantees that we will only take up to 7 working days to get your product up and ready for collection Optional H...

Страница 16: ...ronmental instructions that are covered and prescribed in the operating instructions manual d Any unauthorized repairs e Any alteration or modification made to the Product f Exterior finish or cosmetic damage g Normal usage wear and tear finishes or consumables h Corrosion rusting or stains i Improper transportation inappropriate storage conditions or materials improper ventilation reconfiguration...

Страница 17: ...ility usage of the novita Product This limited warranty will be invalidated and rendered void upon the usage of any non original filters parts accessories that is not approved by novita for the use with the product This limited warranty is void if the serial number on the Product had been removed erased defaced altered tampered or is illegible novita will repair or replace this product at their op...

Страница 18: ... of the terms conditions and limited to standard product warranty coverage Extended limited warranty is available for purchase within the 1 year standard limited warranty period at estore novita com sg nh services An order confirmation email will be sent to your registered email address within 7 working days after receiving th extended limited warranty purchase order and payment and the system wil...

Страница 19: ...novita com sg BW M NH890 V1 COPYRIGHT 2020 NOVITA SG ...