03/10 Rev. 5.04-01
USER MANUAL
Mounting & Setting
LA-BO
4
Adjusting the dispensing edge to the vacuum grid
After fitting the applicator, the position of the dispensing edge in relation to
the vacuum grid of the applicator must be verified and adjusted if necessary.
When viewed from the side, the bottom surface of the vacuum grid must be
slightly below and in front of the dispensing edge (see fig.11).
[Fig. 11]
Position of dispensing edge to vacuum grid.
As a guideline, the center of the dispensing edge should be positioned
approximately 1 mm
above
the vacuum grid surface.
To adjust: Loosen the fixing screws of the angular adjustment of the dispensing
edge, rotate the dispensing edge in the desired position and retighten the
screws.
Parameter settings on the ALX 92x
Menu
Parameter
Value
PRINT PARAMETERS
Dispense position
0 mm (label must be entirely dis-
pensed)
SYSTEM PARAMETERS
Head disp. dist.
24.5 mm
Application mode
Save Mode (recommended for dif-
ficult release of trailing edge of
label material)
APPLICATOR PARA
Applicator type
ASA
Application mode
After start sig.
(preferred setting for maximum
output capacity)
Blow on time
60 ms
[Tab. 1]
The parameter settings required for operating the LA-BO applicator on an ALX 92x.