Operating Manual
LA-BO
AI - parameter settings
The parameter settings required for operating the LA-BO applicator controlled by the
applicator inter-
face
(AI).
The
SIGNAL INTERFACE
>
>AI BOARD SIGNAL
menu appears, if an AI is installed
and
if
SIGNAL
INTERFACE
>
Interface mode
is set to „Applic. signals“.
Menu
Parameter
Setting
LABEL SETUP
Lab. stop offset
19.0 mm (also depending on distance of label
sensor to disp. edge, label must be entirely
dispensed)
SIGNAL INTERFACE
Interface mode
„Applic. signals“
Apply mode
„After start sig.“
(preferred setting for maximum output capacity)
SIGNAL INTERFACE
>AI BOARD SIGNAL
Blow on time
60 ms
MOUNTING & SETTING ON XPA 93X
Montage
This chapter describes how to mount the LA-BO to an XPA 93x machine. The pictures show an XPA
93x (RH). For article numbers refer to chapter
on page 9.
Before you begin
Tool:
• Allen key, 8 mm
Procedure
1.
Screw the applicator to the flange of the XPA 93x using the supplied screws (4x M10x25):
Edition 05 - 08/2022
20
Startup
Mounting & setting on XPA 93x