6
Novell Sentinel™ 6.1 SP1 Hotfix 1
Port number of the SQL Server database.
Name of the SQL Server database to patch (ESEC by default).
2 for the SQL Authentication option.
esecdba user password.
After you press Enter, the script verifies the entered information and proceeds if authentication
is successful.
8
After applying the patch, check for any errors. If there are no errors, the Sentinel Database
patch installation is complete. If there are errors, resolve the errors by referring to the error log
files and re-run the PatchDb utility.
9
After the patch runs with no errors, restart the Sentinel services.
5 Post-Installation
The default date and time format in SCC can be overridden. For customizing the date and time
format to your local timezone, see the
Java Web site (http://java.sun.com/j2se/1.5.0/docs/api/java/
text/SimpleDateFormat.html)
.
1
Edit the
SentinelPreferences.properties
file.
On Windows:
%ESEC_HOME%\config\SentinelPreferences.properties
On UNIX:
$ESEC_HOME/config/SentinelPreferences.properties
2
Uncomment the following line and customize the date and time format for SCC event date/time
fields.
com.eSecurity.Sentinel.event.datetimeformat=yyyy-MM-dd'T'HH:mm:ss.SSSZ
6 Defects Fixed in Sentinel 6.1 SP1 Hotfix 1
This section lists the defects fixed in the Sentinel 6.1 SP1 Hotfix 1.
Table 1
Defects Fixed in Sentinel 6.1 SP1 Hotfix 1
Defect Number
Description
498817
Collector stops working when a Legacy Collector is replaced with a JavaScript
Collector.
498827
Connection Mode used by Event Source should default to the default connection mode
of the Collector, if the configured connection mode is invalid.
498870
The Start and Stop internal events are not generated when starting or stopping the
Javascript Collector.
484423
Collector Manager runs out of memory when a data tap is opened on an active stream
for a prolonged time period.
498871
The ESM does not pay attention to the default attribute for Connection Methods.
459625
SDM lets you create impossible configurations with (at least) MS SQL.