Ex-Power DEFENDER – Operation and Maintenance Manual
Novatio Engineering Confidential Document
3-6
NOTES
•
Exhaust could be visibly cloudy for up to three minutes after cold start-up.
•
Status is normal when Small green LED on AC GFCI outlets is lit while
running engine. If green LED is not lit, reset GFCI switch.
•
If starting the motor takes longer than 30-seconds the red
FAULT
light on the
User Interface panel comes on and the control aborts the start sequence. Turn
the Engine Switch OFF, and then ON again, and re-initiate the Start Sequence.
If there is a problem starting the engine, refer to Troubleshooting in Section 6.1.
After correcting any problems, restart the engine following the steps at the
beginning of this procedure.
8.
If the choke lever was moved to the CLOSED position to start the engine, gradually
move it to the OPEN position as engine warms up.
9.
Apply load after engine ramps up (up to 45 seconds if engine is very cold, immediately if
engine is at typical ambient conditions).
10.
If engine stalls, the operator should remove load, re-set ON/OFF switch and restart
engine.