If this device is not chosen as the primary lightning protection device, the device chosen must meet
the following requirements:
•
UL listed, or equivalent, in country of installation (for example, TUV, VDE and so on) for lightning
surge protection
•
The primary device must be capable of limiting an incoming surge of 10 kV
5. The shield of the coaxial cable entering the building should be connected at a grounding plate at the
building's entrance. The lightning protection devices should have their chassis grounded to the same
ground near to the building's entrance.
6. The primary and secondary lightning protections should be as close to the building's entrance as
possible. Where feasible they should be mounted onto the grounding plate itself. See
Primary and Secondary Lightning Protection
Figure 1: Primary and Secondary Lightning Protection
Ref #
Description
1
Primary lightning protection device
2
Secondary lightning protection device
3
External antenna
4
GNSS Receiver
5
To ground
6
Grounding plate or grounding point at the building’s entrance
Acceptable choices for Earth Grounds, for central buildings, are:
•
Grounded interior metal cold water pipe within five feet (1.5 m) of the point where it
enters the building
•
Grounded metallic service raceway
•
Grounded electrical service equipment enclosure
•
Eight-foot grounding rod driven into the ground (only if bonded to the central
building ground by #6, or heavier, bonding wire)