APPENDIX A IMU Technical Specifications
OEM7 SPAN Installation and Operation User Manual v14
254
Gyroscope Performance
Gyro Input Range
±1000 °/second
Gyro Rate Bias
1.0 °/hour
Gyro Rate Scale Factor
100 ppm
Angular Random Walk
0.07 °/√hour
Accelerometer Performance
Accelerometer Range
±40 g
Accelerometer Linearity
150 ppm
Accelerometer Scale Factor
300 ppm
Accelerometer Bias
0.3 mg
Data Rate
IMU Measurement
200 Hz
Table 140: LN200 IMU Performance