User Manual of
3D Video Controller
www.novastar-led.cn
13
Step 4
Set Cabinet
Out1 QTY
. The device has some limitations on the cabinet quantity of ports. For details, see
precautions for screen setting a).
Step 5
Set the Data Flow(Front View). Pay attention to precautions for screen setting c), d) and e) below.
Precautions for screen setting:
a) If the number of network interfaces with loads
is n (n≤8), the first n
-1 network interfaces must
have the same number of cabinets, which
must also be an integral multiple of the number
of cabinet rows or columns and be greater than
or equal to the number of cabinets for the nth
network interface.
Example:
For example, if network interface 1~7 have loads,
network interface 1~7 must have the same number of
cabinets, which must also be an integral multiple of the
number of cabinet rows or columns. Therefore, you need
only to set
cabinet out1 num
according to the actual
situation when setting the screen. The number of
receiving cards for network interface 8 must be smaller
than or equal to
cabinet out1 num
b) In the case of special-shaped cabinets, different cabinet sizes and special-shaped screen, the
NovaLCT-Mars software is required to be connected to configure the screen.
c)
During connection setting, you can rotate the button to see the effects of different connections on the screen
in real time. If you are satisfied with the connection, you must press the button to save the setting. You can
press the return key to exit from the current operation.
d) During connection setting, you must ensure that the connection of each network interface is downward in
the same direction.
e) During connection setting, you must ensure that network interface 1 is the start position of the whole
connection.
f)
3D HD can load 5.2 million (60Hz) pixels in maximum. The width of lateral load can reach to 3840 pixels in