Novar WHA2 Скачать руководство пользователя страница 5

Jumper links selection: 

 
 
 
 

          Zone jumper links: 
          Z1 
          Z2

 
 
 
 
 
 
 
 

 

PIR LED ENABLE / DISABLE 

When the PIR sensor detects body movement, the green LED will flash for 
approximately 5 seconds indicating transmitting. Disabling the PIR LED will not affect 
the sensing function, but can 

save power

 

JP2 jumper:

  Jumper removed 

 

LED disabled 

  Jumper 

installed 

 LED 

enabled 

< factory default > 

 

 

PIR POWER SAVE ENABLE / DISABLE 

In power save mode, the PIR sensor will not transmit a signal after it has been 
triggered for approximately 5 minutes. When a PIR sensor is in power save mode, it 
will transmit a signal when it detects body movement once. Within the next 5 
minutes, even it has been re-triggered by body movement, it will not transmit a signal 
to 

save power

.    

 

JP1 jumper:

  Jumper removed 

 

Power save enable 

  Jumper 

installed 

 Power 

save 

disable

 

<factory default >

 

Note: Jumpers Z1 and Z2 are not used with your system 

 
 
3.  After configuring the jumpers if necessary, refit the front cover on the sensor. You 

are now ready to test it. 

 

Note: Ensure the front cover is refitted otherwise the PIR will not detect at the 
correct range 

 

 

TEST YOUR SYSTEM 

 

With the sensor installed, check that it functions correctly as follows: 
 

1.  Arm your system using the keypad 
 
2.  Wait for the 30 seconds exit period and the siren beeps once (or will continue 

 

to beep during the exit period if the JP2 jumper on the siren is removed).    

 

 

Содержание WHA2

Страница 1: ...ut of areas protected by the PIR sensor z The maximum number of sensors your system can take is 10 z Do not use rechargeable batteries Only use the equivalent alkaline type z If your alarm system is a...

Страница 2: ...en needs to learn the unique code of this sensor IMPORTANT If your alarm system is already installed and you are adding this accessory to the system then you will need to remove the external siren fro...

Страница 3: ...he siren to exit learn mode manually 5 Refit the back cover and re install the siren on the wall Note that if the tamper switch is activated again another person may be required to disarm it from the...

Страница 4: ...R PIR corner mounted flat wall mounted 0 10 20 30 40 50 10 20 30 40 50 Corner mounted Flat wall mounted PIR PIR PIR detection range when installed to mounting OPTION A or C PIR detection range when in...

Страница 5: ...etects body movement once Within the next 5 minutes even it has been re triggered by body movement it will not transmit a signal to save power JP1 jumper Jumper removed Power save enable Jumper instal...

Страница 6: ...oved and the blue LEDs will flash during the 30 second entry period The alarm will be triggered and its blue LEDs will flash accordingly 5 Disarm your system from the keypad LOW BATTERY WARNING A red...

Страница 7: ...e guarantee states Novar ED S entire liability It does not extent to cover consequential loss or damage or installation costs arising from the defective product This guarantee does not in any way affe...

Отзывы: